a.
Remove the two Phillips M2.0 × 3.0 screws (1) on the top of the hinges.
b.
Remove the four Phillips M2.5 × 2.5 screws (2) on the outside bottom of the hinges and the two
Phillips M2.5 × 4.0 screws (3) at the inside bottom of the hinges.
c.
Remove the display hinges (4).
The display hinges are included in the Display Hinge Kit, spare part number 905560-001.
8.
If it is necessary to replace the display panel cable:
a.
Release the display panel cable from the retention clips (1) and channel built into the left side of
the display back cover.