Procedure
1. Fail over the storage controller
a.
On the StoreVirtual menu, select
Storage Systems
.
a.
On the navigation pane, select the storage system, and then select
Actions
>
Fail over storage
controller
on the content pane.
b.
Select the storage controller from the list if more than one is listed.
a.
Select the check box next to the storage controller status, and then click
Yes, fail over storage
controller
.
2. Reboot the storage controller
a.
On the StoreVirtual menu, select
Storage Controllers
.
b.
On the navigation pane, select the storage controller, and then select
Actions
>
Power off or reboot
on the content pane.
c.
Click
Reboot
.
d.
Enter the number of minutes for the system to wait before rebooting, and then click
OK
.
e.
Review the warning message and then click
Yes, reboot
.
f.
On the second confirmation message, select the confirmation box, and then click
Yes, reboot
.
3. Fail back the storage controller
a.
On the StoreVirtual menu, select
Storage Systems
.
b.
On the navigation pane, select the storage system, and then select
Actions
>
Fail back storage
controller
on the content pane.
c.
Select the storage controller to fail back, and then click
OK
.
Operating the storage system