![HP StoreOnce 4900 Backup Скачать руководство пользователя страница 106](http://html.mh-extra.com/html/hp/storeonce-4900-backup/storeonce-4900-backup_installation-and-configuration-manual_2175247106.webp)
Status
Description
Item
•
Power supply failed
•
Power supply exceeded current limit
Green = Normal operation
System fan LED
6
Amber flashing = Fault
Off = Fan unseated from connector or
Green = System activity
I/O module LED
7
Amber = Fault
Off = Enclosure is powered off.
1 = SES overall warning
7-segment display*
8
2 = Temperature sensor warning
3 = Cooling fan warning
4 = Power supply warning
5 = Host GSI enabled
6 = I/O PIC upgrade needed
7 = Power supply PIC upgrade needed
8 = CPLD upgrade needed
9 = Standby heartbeat failure
10 = Remote I/O module heartbeat failure
11 = Enclosure thermal shutdown imminent
12 = Enclosure thermal shutdown occurred
13 = Enclosure management bus failure, false fan failures may occur
14 = Signal integrity errors detected
15 = Power supply PIC communications error
16 = Unsupported backplane detected
Blue = UID LED is enabled from the UID button
UID button/LED (Drawer 1)
9
Blue flashing = System is in hard drive locate mode or an enclosure
firmware update is in progress.
Off = UID LED is disabled.
* If the GSI is amber, the system needs service. Activate the associated drawer UID button to view
any GSI error codes on the rear display.
106 Understanding LEDs
Содержание StoreOnce 4900 Backup
Страница 47: ...Figure 20 Network configuration flowchart Before running net set wizard 47 ...
Страница 98: ...98 Configuring backup servers to work with HP StoreOnce ...
Страница 101: ...iSCSI Initiator optional VTL only 101 ...
Страница 116: ...Reboot the host Linux system and the connection will work again 1 16 Troubleshooting ...