![HP StorageWorks SR2122 Скачать руководство пользователя страница 194](http://html.mh-extra.com/html/hp/storageworks-sr2122/storageworks-sr2122_user-manual_163205194.webp)
Maintaining and Managing the Storage Router
194
IP Storage Router SR2122-2 User Guide
4.
save scsirouter
scsi2
bootconfig
—
Save the current SCSI
routing instance configuration, including the primary setting, and circulate the
changed configuration around the cluster.
5.
failover scsirouter
scsi2
—
Failover the desired SCSI routing
instance,
scsi2
.
Once the failover is complete, establish a Telnet session to
StorageRouterSys2
and
verify — using the
show scsirouter scsi2
command — that the SCSI
routing instance,
scsi2
, is now running on
StorageRouterSys2
and that
StorageRouterSys2
is designated as the primary storage router for that instance.
Failover for Distribution Purposes
In the example cluster scenario previously described, there is a significant
increase in traffic for SCSI routing instance,
scsi4
, and as a result, you decide to
distribute all of the other instances (
scsi1
,
scsi2
, and
scsi3
) to the
StorageRouterSys1
storage router.
StorageRouterSys1
is already running
scsi1
and
scsi2
.
The following procedure moves the SCSI routing instance,
scsi3
, to
StorageRouterSys1
. The commands in this procedure are issued from a CLI
session from storage router,
StorageRouterSys2
:
1.
enable
— Enter Administrator mode.
2.
show cluster or show scsirouter
scsi3
stats
—
Verify
that the SCSI routing instance to be moved is indeed running on storage
router,
StorageRouterSys2
.
3.
failover scsirouter
scsi3
to
StorageRouterSys1
—
Failover the desired SCSI routing instance,
scsi3
, to
StorageRouterSys1
.
Once the failover is complete, establish a Telnet session to
StorageRouterSys1
and
verify — using the
show scsirouter
command — that instances,
scsi1
,
scsi2
, and
scsi3
, are now running there.
Note:
Because scsi3 has no primary setting, it will remain running on
StorageRouterSys1 until it is explicitly stopped or failed over, or until it automatically
fails over because an interface is unavailable or a software or hardware problem
occurred.
Содержание StorageWorks SR2122
Страница 110: ...Configuring System Parameters 110 IP Storage Router SR2122 2 User Guide ...