Using the CLI
50
Modular Smart Array 1000/1500 cs Command Line Interface User Guide
Server connection commands
Each time the MSA is powered on, all active HBA connections to the MSA are
automatically detected and identified by their WWPN.
Before a server accesses the storage of the MSA, you must identify the operating
system (host mode) of each connection. HP also recommends assigning a
user-defined name to each connection, to make the identification and setup of each
connection easier.
After connections are established, be sure to restrict access to the LUNs to specific
servers. The CLI uses an Access Control List (ACL) to enter the list of LUNs a
server can access. See the following section “
more information about SSP and ACLs.
Each of the following commands is used to enter and manage the connections:
■
■
Setting the connection profile
■
Changing the name of a connection
■
Changing the HBA of a connection
■
Note:
Use the
SHOW CONNECTIONS
command to display information about each HBA
connected to the MSA, including connection name, WWPN, and profile.
The connection name and the WWPN are used when entering connection information.
See
“Viewing connection information” on page 30
for details.