Using the CLI
41
Modular Smart Array 1000/1500 cs Command Line Interface User Guide
Example CLI response
The following display is a continuation of the previous example, creating three
LUNs on the same group of physical drives.
CLI> ADD UNIT 1 DATA=”DISK111-DISK114” RAID_LEVEL=5
STRIPE_SIZE=32 SIZE=1000MB
First volume to be configured on these drives.
The logical unit size has been adjusted by 4MB for optimal
performance.
Logical Unit size = 996 MB
RAID overhead = 498 MB
Total space occupied by new unit = 1494 MB
Free space left on this volume = 24533 MB
Unit 1 is created successfully.
CLI> ADD UNIT 2 DATA=”DISK111-DISK114” RAID_LEVEL=5
STRIPE_SIZE=32 SIZE=2000MB
Logical Unit size = 2000 MB
RAID overhead = 1000 MB
Total space occupied by new unit = 3000 MB
Free space left on this volume = 21533 MB
Unit 2 is created successfully.
CLI> ADD UNIT 3 DATA=”DISK111-DISK114” RAID_LEVEL=5
STRIPE_SIZE=16 SIZE=4000MB
Logical Unit size = 4000 MB
RAID overhead = 2000 MB
Total space occupied by new unit = 6000 MB
Free space left on this volume = 15533 MB
Unit 3 is created successfully.
Содержание StorageWorks Modular Smart Array 1000 cs
Страница 18: ...Overview and Setup 18 Modular Smart Array 1000 1500 cs Command Line Interface User Guide ...
Страница 60: ...Using the CLI 60 Modular Smart Array 1000 1500 cs Command Line Interface User Guide ...
Страница 64: ...Index 64 Modular Smart Array 1000 1500 cs Command Line Interface User Guide ...