Using the CLI
25
Modular Smart Array 1000/1500 cs Command Line Interface User Guide
Viewing LUN information
The following information can be displayed for the LUN:
■
Unit identifier (user-defined name)
■
LUN status, including OK, Failed, and Rebuilding
■
List of the disks included in the LUN
■
List of the disks assigned as spares to the LUN
■
RAID level
■
Unit size, in MB
Basic command
SHOW UNIT
Example command
To display all defined LUNs:
CLI> SHOW UNITS
To display a specific LUN:
CLI> SHOW UNIT 1
Example CLI response
Unit 1:
In PDLA mode, Unit 1 IS LUN 2; In VSA mode, Unit 1 is LUN 1
Unit Identifier:
Device Indentifier:600805F3-00006B20-AE277D4B-B0D100F7
Cache Status:Enabled
Max Boot Partition:Disabled
Volume Status: VOLUME OK
Parity Init Status: 3% complete
5 Data Disk(s) used by lun 1:
Disk107: Box 1, Bay 07, (SCSI bus 0, SCSI id 8)
Disk108: Box 1, Bay 08, (SCSI bus 1, SCSI id 0)
Disk207: Box 2, Bay 07, (SCSI bus 2, SCSI id 8)
Disk208: Box 2, Bay 08, (SCSI bus 2, SCSI id 9)
Spare Disk(s) used by lun 1:
No spare drive is designated.
Logical Volume Raid Level:
DISTRIBUTED PARITY FAULT TOLERANCE (RAID5)
stripe_size=16KB
Logical Volume Capacity: 173,658MB