Installation Instructions

10

universal port module kit installation instructions

4. Secure the UPM card as follows:

CAUTION:  The torque tool supplied with the director is designed to tighten logic cards 
and is set to release at a torque value of six inch-pounds. Do not use an Allen wrench 
or torque tool designed for use with another HP or Compaq product. Use of the wrong 
tool may overtighten and damage logic cards.

a.

Insert the torque tool into the cam Allen screw (uncolored). Turn the torque 
tool clockwise until you feel it release and hear a clicking sound. As the screw 
turns clockwise, the card cams into the backplane connector.

b.

Insert the torque tool into the locking Allen screw (yellow). Turn the torque 
tool clockwise until you feel it release and hear a clicking sound. As the screw 
turns clockwise, the card locks into place.

c.

Verify the card stiffener is flush with the front of the card cage and even with 
other director logic cards.

5. Perform an external loopback test for all ports on the replacement UPM card. For 

instructions, refer to 

External Loopback Test

 and return here. If the test fails, see 

the Maintenance Analysis Procedures (MAP) in the Diagnostics chapter of the 
hp StorageWorks director 2/64 service manual to isolate the problem. 

6. Disconnect the ESD wrist strap from the director chassis and your wrist.

7. Inspect the UPM card to ensure all amber LEDs are extinguished. If any amber 

LEDs are illuminated, go to MAP 0000: Start MAP of the hp StorageWorks 
director 2/64 service manual 
to isolate the problem. 

8. At the HA-Fabric Manager server, open the ha-fabric manager application. The 

Product View displays.

9. Double-click the icon representing the director for which the loopback test will be 

performed. The Hardware View for the selected director displays.

10. Choose Event Log from the Logs menu. The Event Log displays. Ensure the 

following event codes display in the log:

— 500 - UPM card hot-insertion initiated.

— 501 - UPM card hot-insertion completed.

Содержание StorageWorks director 2/140

Страница 1: ...tallation instructions Part Number AA RSS2B TE 958 000281 000 Second Edition November 2002 These installation instructions provide procedures for setting up configuring and managing a UPM kit in an HP StorageWorks Director 2 64 or a Director 2 140 ...

Страница 2: ...r language without the prior written consent of Hewlett Packard The information contained in this document is subject to change without notice All other product names mentioned herein may be trademarks of their respective companies Hewlett Packard Company shall not be liable for technical or editorial errors or omissions contained herein The information is provided as is without warranty of any ki...

Страница 3: ...i Getting Help viii HP Technical Support viii HP Website viii HP Authorized Reseller viii Installation Instructions Supported Kits 1 Installing the UPM 2 Procedural Notes 2 ESD Information 2 Removing the UPM Filler Blank 5 Required Tools 5 Removal 5 Installing the UPM Card 7 Required Tools 7 Installation 8 Miscellaneous Procedures 11 External Loopback Test 11 Unblocking a UPM Card 15 ...

Страница 4: ......

Страница 5: ...orks director 2 64 or the director 2 140 Document Conventions The conventions included in Table 1 apply Table 1 Document Conventions Element Convention Cross reference links Blue text Figure 1 Key names menu items buttons and dialog box titles Bold File names application names and text emphasis Italics User input command names system responses output and messages Monospace font COMMAND NAMES are u...

Страница 6: ...s clarifying information or specific instructions NOTE Text set off in this manner presents commentary sidelights or interesting points of information Symbols on Equipment Any enclosed surface or area of the equipment marked with these symbols indicates the presence of electrical shock hazards Enclosed area contains no operator serviceable parts WARNING To reduce the risk of injury from electrical...

Страница 7: ...tems Any product or assembly marked with these symbols indicates that the component exceeds the recommended weight for one individual to handle safely WARNING To reduce the risk of personal injury or damage to the equipment observe local occupational health and safety requirements and guidelines for manually handling material Rack Stability WARNING To reduce the risk of personal injury or damage t...

Страница 8: ... http thenew hp com country us eng support html Be sure to have the following information available before calling Technical support registration number if applicable Product serial numbers Product model names and numbers Applicable error messages Operating system type and revision level Detailed specific questions HP Website The HP website has the latest information on this product as well as the...

Страница 9: ...ith a base configuration of 64 Fibre Channel ports HP also sells optional kits to increase the number of ports to a maximum of 64 for the Director 2 64 and a maximum of 140 for the Director 2 140 Use the procedures described in this chapter for the following director UPM kits 8 Port UPM Kit 300833 B21 A6574B 2 Short wave 4 Port cards includes 8 short wave 2 Gbps SFP optical transceivers 1 Loop bac...

Страница 10: ...g procedure and continue to the next step of that procedure ESD Information When performing procedures described in this section follow all ESD procedures WARNING statements and CAUTION statements When installing UPMs always connect a grounding cable to the director chassis and wear an ESD wrist strap CAUTION To avoid causing machine errors or damage while working on the director follow ESD proced...

Страница 11: ...Director 2 64 rotate the cable management assembly if used to reach the grounding point The assembly locks into the raised position Any cables attached to the Director 2 64 are then held up allowing access to the lower front of the chassis If no cables are attached to the director the assembly may be removed Figure 1 Director 2 64 ESD grounding point front 1 Director 2 64 ESD Grounding Point PWR O...

Страница 12: ... ESD grounding points As shown in Figure 2 the ESD grounding point for the rear of the Director 2 140 chassis is located next to the maintenance port As shown in Figure 3 the ESD grounding point for the rear of the Director 2 64 chassis is located at the bottom center directly below the maintenance port ...

Страница 13: ... required tools is provided Required Tools The torque tool and hex adapter provided with the director are required to perform the installation procedures Removal To remove a filler blank 1 Unlock and open the cabinet front door if the director is rack mounted and installed in a custom equipment cabinet If the director is installed in a stand alone configuration go to step 2 2 Identify the filler b...

Страница 14: ...the torque tool into each locking Allen screw as shown in Figure 4 for the Director 2 64 and Figure 5 for the Director 2 140 Turn each screw counter clockwise until the spring releases and the tool turns freely Figure 4 Director 2 64 UPM filler blank removal 1 UPM Filler Blank 2 Torque Tool ...

Страница 15: ...ve it from the director chassis Installing the UPM Card Use the following procedures to install a UPM card A list of required tools is provided Required Tools The following tools are required to perform these procedures ESD grounding cable and wrist strap Torque tool and hex adapter provided with the director Fiber optic protective plugs provided with the director ...

Страница 16: ...or follow ESD procedures by connecting a grounding cable to the director chassis and wearing an ESD wrist strap CAUTION Ensure that protective plugs are inserted into the UPM card optical transceiver receptacles This prevents damage to sensitive components and prevents injury to the eye if the laser is viewed directly Figure 6 Director 2 64 UPM card installation 1 UPM Card 2 Torque Tool SHR 2302 S...

Страница 17: ...its stiffener and insert it in the chassis card track as shown in Figure 6 for the Director 2 64 and Figure 7 for the Director 2 140 The yellow locking Allen screw should be at the bottom for the Director 2 64 and it should align with the yellow lock symbols on the frame for the Director 2 140 Verify the card is aligned in the card tracks then slide it forward until it makes contact with the backp...

Страница 18: ...ont of the card cage and even with other director logic cards 5 Perform an external loopback test for all ports on the replacement UPM card For instructions refer to External Loopback Test and return here If the test fails see the Maintenance Analysis Procedures MAP in the Diagnostics chapter of the hp StorageWorks director 2 64 service manual to isolate the problem 6 Disconnect the ESD wrist stra...

Страница 19: ... UPM Card of the hp StorageWorks director 2 64 service manual A6534 96022 AA RS2EA TE Miscellaneous Procedures The following are miscellaneous procedures that you can perform on your UPM card External Loopback Test To perform an external loopback test for a single port or a UPM card four ports 1 If the UPM card is currently being used in a fabric then notify storage users on the fabric that a disr...

Страница 20: ...s b At the Port Card View right click the tested port A menu displays c Choose Reset Port A Reset Port n message box displays where n is the port number d Click OK The port resets e Click Back To Full View to return to the Hardware View 6 Disconnect the fiber optic jumper cable from the port to be tested If a UPM card will be tested disconnect all four fiber optic jumper cables IMPORTANT If name s...

Страница 21: ...lect a UPM card for test type the port number of any of the four ports an the card in the Port Number field then choose All Ports On Card 10 At the Diagnostics Test list box choose External Loopback 11 Click Next Beaconing initiates for the port or UPM card selected for test At the Hardware View a yellow triangle displays at the top of the UPM card At the Port Diagnostics dialog box the following ...

Страница 22: ...hes beacons and the green LED illuminates indicating loopback traffic through the port NOTE Click Stop Test at any time to abort the loopback test 15 When the test completes test results display for each port tested as Port xx Passed or Port xx Failed in the message area of the dialog box If a port fails the test the amber LED for the port remains illuminated 16 When finished click Cancel to close...

Страница 23: ... and right click the mouse to open a list of menu options 5 Choose Unblock All Ports option The Unblock All Ports dialog box displays as shown in Figure 9 Figure 9 Unblock All Ports dialog box 6 Click Yes The following occurs to indicate the UPM card is unblocked and the attached devices are online Emulated green LEDs associated with all four ports illuminate at the Port Card View Green LEDs assoc...

Страница 24: ......

Отзывы: