Installation Instructions
10
universal port module kit installation instructions
4. Secure the UPM card as follows:
CAUTION: The torque tool supplied with the director is designed to tighten logic cards
and is set to release at a torque value of six inch-pounds. Do not use an Allen wrench
or torque tool designed for use with another HP or Compaq product. Use of the wrong
tool may overtighten and damage logic cards.
a.
Insert the torque tool into the cam Allen screw (uncolored). Turn the torque
tool clockwise until you feel it release and hear a clicking sound. As the screw
turns clockwise, the card cams into the backplane connector.
b.
Insert the torque tool into the locking Allen screw (yellow). Turn the torque
tool clockwise until you feel it release and hear a clicking sound. As the screw
turns clockwise, the card locks into place.
c.
Verify the card stiffener is flush with the front of the card cage and even with
other director logic cards.
5. Perform an external loopback test for all ports on the replacement UPM card. For
instructions, refer to
and return here. If the test fails, see
the Maintenance Analysis Procedures (MAP) in the Diagnostics chapter of the
hp StorageWorks director 2/64 service manual to isolate the problem.
6. Disconnect the ESD wrist strap from the director chassis and your wrist.
7. Inspect the UPM card to ensure all amber LEDs are extinguished. If any amber
LEDs are illuminated, go to MAP 0000: Start MAP of the hp StorageWorks
director 2/64 service manual to isolate the problem.
8. At the HA-Fabric Manager server, open the ha-fabric manager application. The
Product View displays.
9. Double-click the icon representing the director for which the loopback test will be
performed. The Hardware View for the selected director displays.
10. Choose Event Log from the Logs menu. The Event Log displays. Ensure the
following event codes display in the log:
— 500 - UPM card hot-insertion initiated.
— 501 - UPM card hot-insertion completed.