40
The server boots but does not recognize the tape drive
The application does not recognize the tape drive
The drive does not work
Possible reason
Recommended action
The power or SCSI cable is not connected
properly.
Check that the cables to the tape drive are firmly
connected. Ensure that the SCSI cable does not have
any bent pins. Replace, if necessary.
The SCSI bus is not terminated correctly.
Check that the SCSI bus is actively terminated. (Refer
also to the documentation for your SCSI controller
and any other SCSI devices you may have.)
The tape drive’s SCSI ID address is not
unique.
Make sure that each device connected to the SCSI
controller has a unique SCSI ID. Remember that 7 is
normally reserved for the host bus adapter. (Users of
most operating systems can run HP Library & Tape
Tools to check the SCSI IDs of each device attached
to the SCSI bus, see page 35.)
Possible reason
Recommended action
The application does not support the tape
drive.
Use HP Library & Tape Tools to check that the drive is
installed properly. Refer to our World Wide Web site
(
www.hp.com/go/connect
) for details of
backup applications that support the
HP StorageWorks DAT tape drive. Load any service
packs as necessary.
Some applications require drivers to be
loaded.
Check that the correct SCSI and tape drive drivers
are installed. Consult the backup application’s
installation notes for details.
Possible reason
Recommended action
If the drive does not power up, the power
cable may not be connected to the drive
properly.
Check the power cable connection and try another
cable if necessary. If the drive still does not power
up, call for service.
If the self-test fails, there may be a hardware
or firmware failure.
If there is a cartridge in the drive, remove it. Power
down the drive and power it up again. If the self-test
still fails, call for service.
There is a hard error on the drive.
The Media Caution (Clean) LED shows steady amber.
Try powering the system off and then on again. If the
error condition signal still shows, call for service.
dds-internal-frame6.fm Page 40 Monday, January 5, 2004 5:01 PM
Содержание StorageWorks DAT 40i
Страница 1: ...getting started guide hp StorageWorks DAT tape drive internal model DAT 40i DAT 72i ...
Страница 2: ...open this flap for quick start installation poster ...
Страница 3: ...5 1 4 ...
Страница 4: ...2 3 6 7 UNIX ...
Страница 14: ...10 2 4 1 8 NC TP 2 4 1 8 NC TP 2 4 1 8 NC TP 3 DEFAULT 6 11 Figure 3 checking the SCSI ID ...
Страница 16: ...12 Figure 4 setting the UNIX configuration switches ...
Страница 22: ...18 Figure 7 installing the drive power cable extension ...
Страница 26: ...22 Figure 9a securing drive to mounting hardware Figure 9b securing drive no mounting hardware ...
Страница 30: ...26 Figure 11 tape drive controls and indicators Eject button Clean LED Tape LED cartridge door ...
Страница 32: ...28 Figure 12 write protecting cartridges tab open cartridge write protected tab closed cartridge write enabled ...
Страница 36: ...32 Figure 13a hp obdr step 1 Figure 13b hp obdr step 2 Figure 13c hp obdr step 3 ...
Страница 49: ......
Страница 50: ...http www hp com go storagemedia http www hp com support dat Printed in the UK C5686 90906 ...