1
switchShow
Display switch and port status.
Synopsis
switchShow
Availability
All users
Description
Use this command to display switch and port status information. Information may vary by switch
model. Below is the information provided. The first section provides switch summary information;
it is followed by a section covering summary information by port.
Switch summary information:
switchName
Switch symbolic name.
switchType
Switch firmware revision number.
switchState
Switch state: online, offline, testing, faulty.
switchRole
Switch role: principal, subordinate, disabled.
switchDomain
Switch domain ID: 0-31 or 1-239.
switchId
Switch embedded port D_ID.
switchWwn
Switch worldwide name.
switchBeacon
The switch's beaconing state (either ON or OFF).
The switch summary is followed by one line per port:
port number
Port number. Valid values vary depending on the switch type.
module type
Port module type (GBIC or other):
-- no module present
sw - shortwave laser
lw - longwave laser
id - serial ID
port speed
The speed of the port:
1G - 1G per second fixed transfer speed
2G - 2G per second fixed transfer speed
N1 - 1G per second negotiated transfer speed
N2 - 2G per second negotiated transfer speed
AN - Auto negotiating
port state
Port state information:
No_Card - no interface card present
No_Module - no module (GBIC or other) present
No_Light - module not receiving light
Содержание StorageWorks 8B - FC Entry Switch
Страница 1: ...reference manual version 3 0 fabric os www hp com ...
Страница 14: ...xiv Fabric OS Reference ...
Страница 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Страница 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Страница 342: ...Index 4 Fabric OS Reference ...