Shared storage—dual controller, optimal cabling, MSA2000sa
This example illustrates optimal cabling for a high-performance, high-availability configuration. In
this configuration, note the following:
•
An additional cable from each switch to each MSA controller offers additional availability
and performance.
•
Connecting each controller to each switch ensures highest availability.
NOTE:
Features of the MSA2000sa and MSA2000sa G2 differ, but cabling and configuration
concepts are the same. This cabling scenario showing the MSA2000sa may also be applied to
the MSA2000sa G2.
Devices and quantities
MSA2000sa controller enclosures: 1
MSA2000 drive enclosures: 0
BladeSystem c7000 enclosures: 1
3Gb SAS BL Switches: 2
Server blade types: half-height and full-height
Connection details
•
Switch in interconnect bay 5:
◦
Port 1: to MSA SAS port A0
◦
Port 2: to MSA SAS port B0
•
Switch in interconnect bay 6:
◦
Port 1: to MSA SAS port A1
◦
Port 2: to MSA SAS port B1
Shared storage—dual controller, optimal cabling, MSA2000sa 103