87
Core Switch 2/64 and SAN Director 2/128 installation guide
4 Installing FRUs
The FRUs in the Core Switch 2/64 and the SAN Director 2/128 can all be removed and
replaced without special tools. Replacement instructions are provided with each replacement
unit ordered. The switch can continue operating during many of the FRU replacements if the
conditions specified in the procedure are followed.
This chapter provides the following topics:
•
Replacing the chassis door
, page 87
•
Replacing the cable management tray
, page 88
•
Replacing the cable guides (pillars)
, page 90
•
Replacing a 16-port card and filler panel
, page 90
•
Replacing a CP card
, page 97
•
Replacing a power supply and filler panel
, page 110
•
Replacing a blower assembly
, page 113
•
Replacing the WWN bezel and card
, page 115
Replacing the chassis door
NOTE:
The chassis door is required to ensure the Core Switch 2/64 and SAN
Director 2/128 meets EMI and other regulatory certifications.
1.
Remove the chassis door from the switch:
a.
Open the door to an angle of approximately 90 degrees.
b.
Support the door to prevent it from falling. Push the spring-loaded pin on the upper
hinge up and into the notch in the hinge (see
Figure 20
), and push the spring-loaded
pin on the lower hinge down and into the notch. Pull the door away from the chassis.
2.
Install the new door in the chassis:
a.
Verify that the levers on the spring-loaded pins on both hinges are pushed into the
notches.
b.
Align the spring-loaded pins with the chassis portion of the hinges.
Содержание StorageWorks 2/64 - Core Switch