Installing FRUs
102
d.
Wait until the Status LED on the healthy CP card is no longer on (indicates failover is
complete).
e.
Enter the
haShow
command from the serial console for the healthy CP card (the new
active CP card) to verify the failover.
6.
Enter the
version
command to record the version of the active CP card.
7.
Enter the
haDisable
command from the active CP card to prevent failover or
communication between the CP cards during the replacement.
8.
From the serial console for the healthy (and active) CP card, back up the current
configuration:
a.
Enter the
configUpload
command.
NOTE:
The
configUpload
command uploads the switch configuration to a specified FTP
server.
Fabric OS (swDir)
swDir login: admin
Password:
swDir:admin>hashow
Local CP (Slot 5, CP0): Active
Remote CP (Slot 6, CP1): Standby
HA Enabled, Heartbeat Up, State Synchronized
swDir:admin>
swDir:admin> hafailover
Forcing Failover...
swDir:admin>
swDir:admin> hashow
Local CP (Slot 5, CP0): Standby
Remote CP (Slot 6, CP1): Active
HA Enabled, Heartbeat Up, State Synchronized
swDir:admin>