79
Core Switch 2/64 and SAN Director 2/128 installation guide
Obtaining chassis and component status
The CLI commands listed in
Table 14
provide status and environmental information about the
chassis and its components. These commands provide information only, and they do not
interrupt traffic flow. For more information about these commands, refer to the
HP
StorageWorks command reference guide
for the Fabric OS version running on your switch
.
NOTE:
The environmental commands report internal temperatures within the chassis. The
16-port cards can withstand internal temperatures of up to 75
o
C and the CP cards can
continue to operate up to 80
o
C. However, the ambient temperature outside the chassis must be
40
o
C or less.
NOTE:
Enter CLI commands with all lowercase characters.
Table 14
Environmental status and maintenance commands
Command
Information displayed
sensorShow
Temperature readings for the port cards
Temperature readings for the CP cards
Status and RPM of all operational fans
Status of all operational power supplies
tempShow
Temperature readings for the port cards
Temperature readings for the CP cards
psShow
Status of all operational power supplies
fanShow
Status and RPM of all operational fans
chassisShow
Serial number, time awake, and additional information about each component
slotShow
Slot occupancy
errShow
Switch error log (lists status of any marginal/failed components)