98
SAN Switch 2/32 Installation Guide
14. Change to /dev and untar the file that was tared in step 4. For example:
tar –xf /tmp/jbod.tar
15. Import the volume groups using vgimport. The proper usage would be
vgimport –m <map file> <path to volume group> <physical volume path>.
For example:
vgimport –m /tmp/jbod_map /dev/jbod /dev/dsk/c64t8d0
/dev/dsk/c64t9d0
16. Activate the volume groups using vgchange. The proper usage would be
vgchange –a y <path to the volume group>. For example:
vgexport –a y /dev/jbod
17. If you are not using multi-pathing software, mount all devices again and
restart I/O. For example,
mount /mnt/jbod
18. If you are using multi-pathing software, re-enable the affected path. The
preceding steps do not “clean up” the results from ioscan. When viewing the
output of ioscan, notice the that the original entry is still there, but now has a
status of NO_HW.
Figure 20: ioscan output
19. To remove the original (outdated) entry, use the command
rmsf
(remove
special file). For example:
rmsf –a –v /dev/dsk/c65t8d0
20. Validate that the entry has been removed by using the command
ioscan
–funC
disk
. Notice in the figure below that the NO_HW entry is no longer
listed.
# ioscan -funC disk
Class
I
H/W Path
Driver S/W State
H/W Type
Description
-------------------------------------------------------------------------------------
disk
0
0/0/1/1.2.0
adisk CLAIMED
DEVICE
SEAGATE ST39204LC
/dev/dsk/clt2d0 /dev/rdsk/c1t2d0
disk
1
0/0/2/1.2.0
adisk CLAIMED
DEVICE
HP
DVD-ROM 304
/dev/dsk/c3t2d0 /dev/rdsk/c3t2d0
disk
319 0/4/0/0.1.2.255.14.8.0
adisk CLAIMED
DEVICE
SEAGATE ST336605FC
/dev/dsk/c64t8d0 /dev/rdsk/c64t8d0
disk 320
0/4/0/0.1.18.255.14.8.0
adisk
NO_HW
DEVICE SEAGATE
ST336605FC
/dev/dsk/c65t8d0 /dev/rdsk/c65t8d0
Содержание StorageWorks 2/32 - SAN Switch
Страница 8: ...Contents 8 SAN Switch 2 32 Installation Guide ...
Страница 22: ...Overview 22 SAN Switch 2 32 Installation Guide ...
Страница 60: ...Installing the SAN Switch 2 32 60 SAN Switch 2 32 Installation Guide ...
Страница 78: ...Managing the SAN Switch 2 32 78 SAN Switch 2 32 Installation Guide ...
Страница 84: ...Backing Up the Configuration and Upgrading Firmware 84 SAN Switch 2 32 Installation Guide ...
Страница 106: ...Regulatory Compliance Notices 106 SAN Switch 2 32 Installation Guide VCCI EMC Statement Japan ...
Страница 107: ...Regulatory Compliance Notices 107 SAN Switch 2 32 Installation Guide BSMI EMC Statement Taiwan ...
Страница 108: ...Regulatory Compliance Notices 108 SAN Switch 2 32 Installation Guide RRL EMC Statement Korea ...
Страница 126: ...Index 126 SAN Switch 2 32 Installation Guide ...