System Unit
Dimensions
(H x W x D)
(with bezel)
3.44 x 17.64 x 32.28 in (8.74 x 44.81 x 82 cm)
Weight
(approximate)
1U LFF full loading system(12 HDDs, power supply, and processor
installed):37.50kg
1U SFF full loading system(24 HDDs, power supply, and processor
installed):35.52kg
2U LFF full loading system(12 HDDs, power supply, and processor
installed):33.395kg
2U SFF full loading system(24 HDDs, power supply, and processor
installed):31.345kg
Input Requirements
(per power supply)
Rated Line Voltage
90 to 140 VAC
180 to 264 VAC
Rated Input Current
7.31A at 115VAC
3.6A at 230VAC
Rated Input Frequency
47 to 63 Hz
Rated Input Power
855W (at 100 VAC),
840.72W (at 200 VAC)
Power Specifications
NOTE:
To review typical system power ratings use the HP Power Advisor
which is available online located at url:
www.hp.com/go/proliant-energy-
efficient
or
www.hp.com/go/hppoweradvisor
Power Supply Output
(per power supply)
Rated Steady-State Power 653.10W (at 100 VAC),
653.08W (at 200 VAC)
System Inlet
Temperature
Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per every 1000 ft (1.0°C
per every 304.8 m) above sea level to a maximum
of 10,000 ft (3048 m), no direct sustained
sunlight. Maximum rate of change is 18°F/hr
(10°C/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 86°F (30°C).
Non-operating
40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative Humidity
(non-condensing)
Operating
10% to 85% relative humidity (Rh), 82.4°F (28°C)
maximum wet bulb temperature, non-
condensing.
Non-operating
10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature, non-
condensing.
Altitude
Operating
10,000 ft (3048 m). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Non-operating
30,000 ft (9144 m). Maximum allowable altitude
change rate is 1500 ft/min (457 m/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
QuickSpecs
HP SL2500 Scalable System
Technical Specifications
DA - 14656 North America — Version 6 — December 9, 2013
Page 43