HP ProLiant DL140 Server Setup and Installation Guide
35
System BIOS Update
The server provides three modes for system BIOS upgrade with flash tools
1.
DOS mode
2.
Recovery Mode
The steps for DOS mode BIOS ROM upgrade
1.
Extract the current BIOS ROM image to a 1.44MB bootable floppy disk.
2.
Insert the floppy disk into a USB floppy drive and attach drive to the system.
3.
Make sure that the floppy drive is the first in the boot priority.
4.
Reboot the system.
5.
Follow the steps outlined in the accompanying readme.txt file
6.
Do not turn off the system or break execution during flash process executing. These
abnormal actions will cause the ROM to become corrupt.
7.
After the ROM upgrade is finished, remove power to the system and reboot.
The steps for use of Recovery Mode (general procedure-see readme.txt for specific information)
1.
Obtain a floppy disk and format it(i.e. format a:)
2.
Copy or extract the .ROM file onto the floppy disk.
3.
Set DIP switch SW1-3 to the ON position.
4.
Install the recovery diskette into a USB floppy drive.
5.
Boot-up the system through the USB floppy drive, the system will automatically execute the
recovery mode ROM flash.
6.
When complete, the server will beep 4 times.
7.
Set DIP switch SW1-3 back to the OFF position.
8.
Cycle AC power and reboot the server.
IPMI Event Log
The IPMI Event Log is a log that is generated by management controllers when they detect
significant or critical system management events. This includes messages for events such as
‘temperature threshold exceeded’, ‘voltage threshold exceeded’, ‘power fault’, etc. The Event
Log generator (the device generating an Event Log) notifies the system of the event by sending an
“Event Request Log” to the Event Receiver Device.
Refer to Intelligent Platform Management Interface (IPMI) Specification v1.0, Document
Revision 1.1, November 15, 1999