System Unit
Dimensions
(H x W x D)
(with bezel)
Single-width: 7.11 x 2.18 x 20.37 in (18.07 x 5.54 x 51.76 cm)
Double-width: 7.11 x 4.46 x 20.37 in (18.07 x 11.08 x 51.76 cm)
Weight
(approximate)
(Single-width type)
Maximum: all processors,
16 DIMMs, hard drives,
mezzanine cards, and two
flash cache batteries
installed)
14.00 lb (6.33 kg)
Minimum: one processor
and 2 DIMMs installed
10.50 lb (4.75 kg)
(Double-width type)
Maximum: all processors,
16 DIMMs, hard drives,
mezzanine cards, and two
flash cache batteries
installed), dual MultiGPU
Carrier with eight Q1000M
22.25 lb (10.09 kg)
Minimum: one processor
and 2 DIMMs installed,
expansion blade slot 1,2
enabled, both slots vacant
15.69 lb (7.12 kg)
Power Specifications
For power specifications including input requirements, BTU rating, and power
supply output, please see the:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_na/
12790_na.html
HP BladeSystem c7000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12810_na/
12810_na.html
To review typical system power ratings use the HP Power Advisor which is
available via the online tool located at:
http://www.hp.com/go/bladesystem/powercalculator
System Inlet Temperature
(Single-width type)
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight.
Maximum rate of change is 10°C/hr (18°F/hr). The
upper limit may be limited by the type and
number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
QuickSpecs
HP ProLiant WS460c Gen8 Workstation Blade
Technical Specifications
DA - 14409 North America — Version 16 — December 13, 2013
Page 49