Install a server drive in the cage
Prerequisites
Before you perform this procedure, make sure that you have a T-10 screwdriver available.
Procedure
1.
Install the drive in the cage.
Make sure that the drive connector is on the same side as the arrow marker on the cage.
2.
Install the drive screws.
1
2
2
Replacing the drive SATA-power Y-cable
Procedure
1. Prepare the server for hardware replacement
.
3.
If installed,
remove the communication board
4.
Perform the step applicable to your situation:
• If you are replacing the drive 1 SATA-power Y-cable or are replacing the SATA-power Y-cables for both
remove both server drive assemblies
• If you are only replacing the server drive 2 SATA-power Y-cable,
remove only the drive 2 assembly
5. Remove the drive SATA-power Y cable
6. Connect the new drive SATA-power Y-cable