Component identification 16
o
Drives in the second box correspond to node 3.
Hot-plug drive LED definitions
Item LED
Status
Definition
1
Locate
Solid blue
The drive is being identified by a host application.
Flashing blue
The drive carrier firmware is being updated or requires an update.
2
Activity ring
Rotating green
Drive activity
Off
No drive activity
3
Do not remove
Solid white
Do not remove the drive. Removing the drive causes one or more of
the logical drives to fail.
Off
Removing the drive does not cause a logical drive to fail.
4
Drive status
Solid green
The drive is a member of one or more logical drives.
Flashing green
The drive is rebuilding or performing a RAID migration, strip size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
amber/green
The drive is a member of one or more logical drives and predicts
the drive will fail.
Flashing amber The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
Содержание ProLiant SL210t Gen8
Страница 60: ...Cabling 60 RPS cabling FBWC capacitor pack cabling 1U node 2U node ...
Страница 61: ...Cabling 61 System board Mini SAS cabling 1U node configuration Two LFF drives per node Six SFF drives per node ...
Страница 62: ...Cabling 62 2U node configuration Four LFF drives per node Six SFF drives per node ...
Страница 63: ...Cabling 63 GPU power cabling Mini SAS P222 cabling 1U node ...
Страница 64: ...Cabling 64 2U node with two LFF drives per node Mini SAS P420 LFF cabling 1U node ...
Страница 65: ...Cabling 65 2U node with four LFF drives per node Mini SAS P420 SFF cabling 1U node 2U node ...
Страница 66: ...Cabling 66 o Twelve SFF drives per node o Six SFF drives per node ...
Страница 67: ...Cabling 67 Mini SAS P430 cabling 1U node 2U node o Four LFF drives per node ...
Страница 69: ...Cabling 69 ...
Страница 94: ...Support and other resources 94 ...
Страница 95: ...Support and other resources 95 ...