Removal and Replacement Procedures 53
3.
Install the power supply blank into the place where power supply was seated.
Figure 34
Removing the power supply
To install the power supply:
1.
Remove the power supply blank out of the power cage.
2.
Align the power supply cage connector with the open slot of power supply.
3.
Slide the power supply into the power supply bay until it snaps into place.
Figure 35
Installing the power supply
System Fan
The server can support 8 system fans located at the chassis’ rears fan cage.
The figure below identifies the system fans by their device number and shows their corresponding
cable connections.