System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (HxWxD)
(with feet)
14.38 x 6.9 x 16.8 in (36.52 x 17.5 x 42.6 cm)
Weight
Weight
Weight
Weight (approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
30.53 lb (13.85 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
25.13 lb (11.4 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
90 to 132 VAC,
180 to 264 VAC
Rated Input Current
5 A (at 100 VAC),
2.5 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
400 W (at 100 VAC),
400 W (at 200 VAC)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical power ratings use the Power Advisor which is available via
the online tool located at URL:
http://www.hp.com/go/hppoweradvisor
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power 300 W (at 100 VAC),
300 W (at 200 VAC)
Maximum Peak Power
300 W (at 100 VAC),
300 W (at 200 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3048 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System may shut down if operating with a fan
fault or above 42°C °(107.6°F).
Non-operating
-35° to 65°C (-31° to 149°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
10% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 609
m/min (2000 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 609 m/min (2000 ft/min).
QuickSpecs
HP ProLiant ML110 Generation 6 (G6)
HP ProLiant ML110 Generation 6 (G6)
HP ProLiant ML110 Generation 6 (G6)
HP ProLiant ML110 Generation 6 (G6)
Technical Specifications
DA - 13477 Worldwide — Version 6 — May 6, 2010
Page 27