background image

Part Number

Part Number

Part Number

Part Number

445067-001

Operational Input Voltage Range

Operational Input Voltage Range

Operational Input Voltage Range

Operational Input Voltage Range
(Vrms)

100 to 127 and 200 to 240 V auto ranging

Frequency Range

Frequency Range

Frequency Range

Frequency Range (Nominal) (Hz)

50 to 60 Hz

 

 

 

 

 

Nominal Input Voltage

Nominal Input Voltage

Nominal Input Voltage

Nominal Input Voltage (Vrms)

100

100

100

100

120

120

120

120

200

200

200

200

230

230

230

230

240

240

240

240

Max Rated Output Wattage Rating

300

300

300

300

300

Nominal Input Current (A rms)

5

5

2.5

2.5

2.5

Max Rated Input Wattage Rating
(Watts)

400

N/A

N/A

400

N/A

Max. Rated VA (Volt-Amp)

400

N/A

N/A

400

N/A

Efficiency (%)

80%

80%

80%

80%

80%

Power Factor

0.9

N/A

N/A

0.9

N/A

Leakage Current (mA)

3.5mA

N/A

N/A

N/A

N/A

Maximum Inrush Current (A peak)

N/A

No component

was damaged

and input fuse

shall not blow

N/A

No component

was damaged

and input fuse

shall not blow

N/A

Maximum Inrush Current duration (mS)

N/A

N/A

N/A

N/A

N/A

QuickSpecs

HP ProLiant ML110 Generation 6 (G6)

HP ProLiant ML110 Generation 6 (G6)

HP ProLiant ML110 Generation 6 (G6)

HP ProLiant ML110 Generation 6 (G6)

Power Specifications

DA - 13477   Worldwide — Version 6 — May 6, 2010

Page 25

Содержание ProLiant ML110 Generation 6 (G6)

Страница 1: ...10 300W Power Supply 10 Management NIC port RJ 45 11 Video port 12 Serial port 13 USB ports 14 Embedded NIC port RJ 45 15 PS 2 keyboard port 16 PS 2 mouse port 17 Power supply cable socket What s New What s New What s New What s New Support for 4GB UDIMM Support for embedded HP Smart Array B110i SATA RAID Controller RAID 0 1 10 At A Glance At A Glance At A Glance At A Glance Processor Processor Pr...

Страница 2: ...P ProLiant ML110 G6 Easy Set up CD Integrated HP ProLiant 100 G6 Lights Out 100i Remote Management Operating System Operating System Operating System Operating System Supports Windows including Hyper V RHEL and SLES Form Factor Form Factor Form Factor Form Factor Micro ATX tower 4U NOTE NOTE NOTE NOTE Rack mounting available via HP Tower to Rack Conversion Tray Universal Kit Please see the options...

Страница 3: ...eron processor G1101 2 26GHz 73W 2MB 1066 NOTE NOTE NOTE NOTE Available through Configure To Order only See Factory Integration Models section for more details NOTE NOTE NOTE NOTE HT indicates that the processor model supports Intel Hyper Threading Technology NOTE NOTE NOTE NOTE Turbo indicates the maximum potential frequency increment when using Intel Turbo Boost Technology with 4 3 2 and 1 cores...

Страница 4: ...Hard Disks NOTE NOTE NOTE NOTE Transfer rate 3 Gb s SATA Embedded HP Smart Array B110i SATA RAID Controller RAID 0 1 10 NOTE NOTE NOTE NOTE Support up to four 4 3 0Gb s SATA hard disk drives only NOTE NOTE NOTE NOTE For set up instructions refer to the HP ProLiant ML100 series server user guide at http bizsupport1 austin hp com bc docs support SupportManual c01708878 c01708878 pdf NOTE NOTE NOTE N...

Страница 5: ...to Rack Conversion Tray Universal Kit Please see the options section in this QuickSpecs Embedded Manageability Embedded Manageability Embedded Manageability Embedded Manageability HP LO100i Advanced HP LO100i Advanced HP LO100i Advanced HP LO100i Advanced HP LO100i Lights Out 100 with Optional LO100i Advanced Licenses for Virtual KVM and Virtual Media Features Embedded IPMI standard reporting Syst...

Страница 6: ...orted ProLiant software can be installed NOTE NOTE NOTE NOTE For the latest information about other related software please visit the HP Insight Control Management Software Portfolio at http h18004 www1 hp com products servers management and the HP ProLiant Easy Set up CD Web site at www hp com servers easysetup Industry Standard Industry Standard Industry Standard Industry Standard Compliance Com...

Страница 7: ...erver Power Cords Server Power Cords Server Power Cords Server Power Cords 6 country specific lowline NEMA power cord Power Supply Power Supply Power Supply Power Supply 300 Watts Non Hot Plug Non redundant Power Supply 80 efficiency System Fans System Fans System Fans System Fans One 1 Non redundant system fan shipped standard One 1 Non redundant CPU heatsink fan shipped standard Operating System...

Страница 8: ...o the enclosure as well as 22 and smaller external monitors and rack mounted UPS options HP Uninterruptible Power Systems will be covered at the same service level and coverage period as the server Coverage of UPS Battery is not included and standard warranty terms conditions apply For servers or storage systems installed within a rack service also covers all HP qualified rack options installed wi...

Страница 9: ...iant carepack QuickSpecs HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 Generation 6 G6 Standard Features DA 13477 Worldwide Version 6 May 6 2010 Page 9 ...

Страница 10: ...mote Management HP Half Height 16x SATA DVD ROM Mouse Keyboard Mouse Keyboard Mouse Keyboard Mouse Keyboard None ships standard Form Factor Form Factor Form Factor Form Factor Micro ATX Tower 4U Base Model Base Model Base Model Base Model HP ML110 G6 X3430 HP ML110 G6 X3430 HP ML110 G6 X3430 HP ML110 G6 X3430 NHP SATA Server NHP SATA Server NHP SATA Server NHP SATA Server 506667 xx1 Processor Proc...

Страница 11: ...age 4 0TB 4 x 1 0TB Non hot plug LFF SATA Maximum Power Supply Power Supply Power Supply Power Supply 300W Non Hot Plug Non Redundant Power Supply 80 efficiency Networking Networking Networking Networking Embedded NC107i PCI Express Gigabit Ethernet Server Adapter Management Management Management Management Optical Drive Optical Drive Optical Drive Optical Drive Integrated HP ProLiant 100 G6 Light...

Страница 12: ... SATA RAID Controller go to http h18004 www1 hp com products servers proliantstorage arraycontrollers smartarrayb110i index html Non hot plug SAS SATA 4 port cable Easy set up CD PCA Power cord Micro ATX Tower 4U Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Ch...

Страница 13: ...ve 454234 B21 HP 300GB 3G SAS 15K LFF 3 5 inch Non hot Plug Dual Port ENT 3y Wty Hard Drive 417950 B21 HP 146GB 3G SAS 15K LFF 3 5 inch Non hot Plug Dual Port ENT 3y Wty Hard Drive 417855 B21 HP Storage Controllers HP Storage Controllers HP Storage Controllers HP Storage Controllers SAS Controller SAS Controller SAS Controller SAS Controller NOTE NOTE NOTE NOTE Support for SAS hard drives tape dri...

Страница 14: ...72 B21 HP 500GB 3G SATA 7 2K rpm LFF 3 5 inch Non hot Plug Midline 1y Wty Hard Drive 458941 B21 SATA Non Hot Plug LFF 3 5 inch Entry ETY Drives SATA Non Hot Plug LFF 3 5 inch Entry ETY Drives SATA Non Hot Plug LFF 3 5 inch Entry ETY Drives SATA Non Hot Plug LFF 3 5 inch Entry ETY Drives HP 250GB 3G SATA 7 2K rpm LFF 3 5 inch Non hot Plug Entry 1y Wty Hard Drive 571232 B21 HP 160GB 3G SATA 7 2K rpm...

Страница 15: ...apter 394791 B21 HP NC382T PCI Express Dual Port Multi function Gigabit Server Adapter 458492 B21 NOTE NOTE NOTE NOTE Please see the QuickSpecs for Technical Specifications and additional information www hp com go ProLiantNICs QuickSpecs HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 Generation 6 G6 Core Options DA 13477 Worl...

Страница 16: ...ptional Upgrades Optional Upgrades Optional Upgrades Optional Upgrades 256 MB Cache Module 462968 B21 Battery Kit upgrade NOTE NOTE NOTE NOTE Required to enable BBWC on the 256MB cache 462969 B21 NOTE NOTE NOTE NOTE Please see the following QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 13203_div 13203_div html Smart Array P212 Contro...

Страница 17: ...e server Connection using the HP SC44Ge SAS Host Bus Adapter 416096 B21 recommended DW085A HP Disk Backup HP Disk Backup HP Disk Backup HP Disk Backup NOTE NOTE NOTE NOTE For the complete range of StorageWorks D2D Backup Systems see http www hp com go d2d For the complete range of StorageWorks RDX drives and media see http www hp com go rdx For hardware and software compatibility of HP StorageWork...

Страница 18: ...uickSpecs for Technical Specifications such as height width depth weight and color http h18000 www1 hp com products quickspecs 12402_div 12402_div html Worldwide NOTE NOTE NOTE NOTE For additional information regarding Rack Cabinets please see the following URL http www hp com go rackandpower Worldwide HP Rack Options HP Rack Options HP Rack Options HP Rack Options HP KVM Switch Options HP KVM Swi...

Страница 19: ...r On site Service Hardware Services 4 Hour On site Service Hardware Services 4 Hour On site Service Hardware Services 4 Hour On site Service 13 Hour x 5 Day Coverage 3 Years Electronic U4434E 24 Hour x 7 Day Coverage 3 Years Electronic U4435E Hardware Services 6 Hour Call to Repair On Site Service Hardware Services 6 Hour Call to Repair On Site Service Hardware Services 6 Hour Call to Repair On Si...

Страница 20: ...pty Empty Empty Empty 2 GB 2 GB 2 GB 2 GB Empty Empty Empty Empty Empty Empty Empty Empty Standard Base Standard Base Standard Base Standard Base Model Model Model Model 2 GB 2 GB 2 GB 2 GB Empty Empty Empty Empty 2 GB 2 GB 2 GB 2 GB Empty Empty Empty Empty Empty Empty Empty Empty Standard Standard Standard Standard Performance Performance Performance Performance Model Model Model Model 4 GB 4 GB ...

Страница 21: ...tity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller Removable Media Removable Media Removable Media Removable Media DVD Drive 2 1 or 2 Integrated SATA DVD RW Drive 2 1 or 2 Integrated SATA QuickSpecs HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 G...

Страница 22: ... 3 5 inch Enterprise ENT Drives SAS Non Hot Plug LFF 3 5 inch Enterprise ENT Drives SAS Non Hot Plug LFF 3 5 inch Enterprise ENT Drives NOTE NOTE NOTE NOTE SAS non hot plug drives require HP SAS Smart Array Controller Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controll...

Страница 23: ...pe Libraries Tape Libraries Tape Libraries Tape Libraries MSL2024 MSL4048 MSL8096 MSL6000 External HP U320e SCSI Dual Channel Controller Please check the full compatibility information at http www hp com go connect AH627A HP StorageWorks SAS HP StorageWorks SAS HP StorageWorks SAS HP StorageWorks SAS Tape Autoloaders and Tape Autoloaders and Tape Autoloaders and Tape Autoloaders and Libraries Libr...

Страница 24: ...Works D2D HP StorageWorks D2D HP StorageWorks D2D Backup Systems iSCSI Backup Systems iSCSI Backup Systems iSCSI Backup Systems iSCSI D2D2500i External Embedded Network Controller If the server requires a hardware iSCSI initiator the QLogic QLA4050 Host Bus Adapter is recommended QuickSpecs HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 Generation 6 G6 HP ProLiant ML110 Generation 6 G6 HP Pro...

Страница 25: ...utput Wattage Rating 300 300 300 300 300 Nominal Input Current A rms 5 5 2 5 2 5 2 5 Max Rated Input Wattage Rating Watts 400 N A N A 400 N A Max Rated VA Volt Amp 400 N A N A 400 N A Efficiency 80 80 80 80 80 Power Factor 0 9 N A N A 0 9 N A Leakage Current mA 3 5mA N A N A N A N A Maximum Inrush Current A peak N A No component was damaged and input fuse shall not blow N A No component was damage...

Страница 26: ...rds Power Cords Power Cords Power Cords 13 Cord Sets Power Cord Part Number Power Cord Part Number Power Cord Part Number Power Cord Part Number Country Country Country Country Taiwan 393312 001 Japan 139867 005 India 397138 002 Brazil 285052 001 Australia 100661 001 Euro 100614 009 PRC 286496 001 UK 100613 008 US 121565 001 ITL 109197 008 NOTE NOTE NOTE NOTE To review typical system power ratings...

Страница 27: ... System Inlet Temperature System Inlet Temperature Operating 10 to 35 C 50 to 95 F at sea level with an altitude derating of 1 0 C per every 304 8 m 1 8 F per every 1000 ft above sea level to a maximum of 3048 m 10 000 ft no direct sustained sunlight Maximum rate of change is 10 C hr 18 F hr The upper limit may be limited by the type and number of options installed System may shut down if operatin...

Страница 28: ...SATA HP 160GB 3G SATA HP 160GB 3G SATA 7 2K rpm LFF 3 5 inch 7 2K rpm LFF 3 5 inch 7 2K rpm LFF 3 5 inch 7 2K rpm LFF 3 5 inch Non hot Plug Entry 1y Non hot Plug Entry 1y Non hot Plug Entry 1y Non hot Plug Entry 1y Wty Hard Drive Wty Hard Drive Wty Hard Drive Wty Hard Drive 458947 B21 160GB 7 200 rpm 160GB 7 200 rpm 160GB 7 200 rpm 160GB 7 200 rpm Capacity Capacity Capacity Capacity 160 041MB Heig...

Страница 29: ...ht 16X Max HP Half Height 16X Max HP Half Height 16X Max SATA DVD ROM Optical SATA DVD ROM Optical SATA DVD ROM Optical SATA DVD ROM Optical Drive Drive Drive Drive Disk Disk Disk Disk Applicable Disk CD ROM CD XA CD DA Mode 1 Mode 2 Form 1 and 2 Photo CD Single and Multi session Mixed Mode Audio and Data combined CD R CD RW DVD ROM DVD R DVD RW Capacity 4 7 GB DVD 5 8 54 GB DVD 9 Block Size Block...

Страница 30: ...ife HP product return trade in and recycling programs in many geographic areas For trade in information please go to http www hp com go green To recycle your product please go to http www hp com go green or contact your nearest HP sales office Products returned to HP will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide...

Отзывы: