System battery replacement 49
System battery replacement
System battery information
The server contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery
that provides power to the real-time clock. If this battery is not properly handled, a risk of the fire and burns
exists. To reduce the risk of personal injury:
•
Do not attempt to recharge the battery.
•
Do not expose the battery to temperatures higher than 60°C (140°F).
•
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
•
If the server no longer automatically displays the correct date and time, then replace the battery that
provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
Replacing the system battery
Required tools:
•
No. 2 Phillips screwdriver
•
Flat-nose pliers (small)
Process overview:
1.
Prepare the server for hardware installation or removal (on page
2.
If the server is installed in a cradle, wall mount, or storage expansion unit, do one of the following:
o
Remove the server from the cradle (on page
o
Remove the server from the wall mount (on page
o
Remove the server from the storage expansion unit (on page
3.
Remove the access panel (on page
4.
If installed, remove the communication board.
a.
Remove the RJ-45 port bracket.
Содержание ProLiant EC200a
Страница 13: ...Component identification 13 Fan location in the storage expansion unit ...
Страница 43: ...Cabling 43 Fan cabling Ambient temperature sensor cabling ...
Страница 65: ...Support and other resources 65 ...
Страница 66: ...Support and other resources 66 ...
Страница 67: ...Support and other resources 67 ...