Table 2 outlines the power redundancy behavior of the DL580 G5 when this option is set in RBSU. Customers interested in this option
need to first consult the Active Answers Power Calculator to confirm their power is redundant with their system configuration.
Power Supply Override Enabled
Power Supply Override Enabled
Power Supply Override Enabled
Power Supply Override Enabled
1
(1+ Redundancy)
Customers must consult the power calculator with their system configuration to verify if the server configuration is redundant before
enabling this option.
Number of Power
Supplies
Hi-Line
(208VAC and higher)
Low-Line
(115VAC and lower)
1 to 4 Processors
1 to 2 Processors
3 to 4 Processors
Supported at
POST
Redundant
Supported at
POST
Redundant
Supported at
POST
Redundant
1
Yes
2
No
Yes
2
No
Yes
2
No
2
Yes
Consult Power
Calculator
Yes
Consult Power
Calculator
Yes
Consult Power
Calculator
3
Yes
Yes
Yes
4
Yes
Yes
Yes
Table 2
Table 2
Table 2
Table 2
NOTES:
NOTES:
NOTES:
NOTES:
When this selection has been set in RBSU, a "Power Supply Requirements Override has been enabled" message will be
displayed during POST.
In a one supply configuration, the external health LED will flash to warn that system is not redundant.