background image

Disk partitioning and RAID con

fi

guration (ML110 G2

Workgroup)

The four hard drives included in the ML110 G2 (Workgroup) storage

server is con

fi

gured for hardware RAID fault tolerance using the Adaptec

2410SA SATA RAID Controller.

The OS logical drive is con

fi

gured as a 9 GB RAID 5 mirror

spanning drives 0, 1, 2 and 3.

The data volume is con

fi

gured as a RAID 5 volume spanning

across all drives.

Table 14 RAID con

fi

guration by hard drives

Hard Drive 0

Partition C: 9GB OS Partition E: User Data in

RAID-5

Hard Drive 1

Partition C: 9GB OS Partition E: User Data in

RAID-5

Hard Drive 2

Partition C: 9GB OS Partition E: User Data in

RAID-5

Hard Drive 3

Partition C: 9GB OS Partition E: User Data in

RAID-5

Table 15 RAID con

fi

guration by logical drives

Logical Drive 1

Partition C: 9GB Primary OS - RAID 5 Mirror

across physical drives 0 and 1

Logical Drive 2

Partition E: 9GB Data volume using remaining

disk space - RAID 5 volume is striped across

physical drives 0, 1, 2 and 3

NOTE:

In Adaptec Storage Manager, logical disks are labeled 1 and 2. In

Disk Manager, logical disks are displayed as 0 and 1. The default

con

fi

guration for the data volume can be modi

fi

ed using the Disk

Management utility. Refer to the administration guide for additional

information.

The BIOS supports the following default boot sequence:

HP ProLiant Storage Server user guide

51

Содержание ProLiant DL580 G2

Страница 1: ...HP ProLiant Storage Server user guide Part number 378128 004 Fourth edition June 2005 ...

Страница 2: ...ject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting as additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Microsoft MS Windows Windows and Windows NT are U S registered trademar...

Страница 3: ...oying the storage server on the network 21 IP networking and setup requirements 21 Collecting configuration information 22 Windows Multilingual User Interface MUI on Storage Server Service Release DVD 23 WebUI configuration 23 Method 1 Remote browser using hostname 24 Procedure 24 Method 2 Direct attach 25 Procedure 25 Rapid Startup Wizard configuration 26 Procedure 27 Completing basic setup 29 Co...

Страница 4: ...n 41 Disk Manager 43 Disk partitioning and RAID configuration ML110 G1 and DL100 43 Storage for ML110 G2 HP ProLiant Storage Servers 46 Physical drive configuration 46 ML110 G2 Express 46 ML110 G2 Workgroup 47 Disk Manager 48 Disk Partioning and RAID configuration ML110 G2 Express 48 Disk partitioning and RAID configuration ML110 G2 Workgroup 51 Storage for 300 series and 500 series ProLiant stora...

Страница 5: ...lish notice 59 Dutch notice 60 Czechoslovakian notice 60 Estonian notice 61 Finnish notice 61 French notice 61 German notice 62 Greek notice 62 Hungarian notice 63 Italian notice 63 Latvian notice 64 Lithuanian notice 64 Polish notice 65 Portuguese notice 65 Slovakian notice 65 Slovenian notice 66 Spanish notice 66 Swedish notice 67 B Electrostatic Discharge 69 Grounding methods 69 Index 71 HP Pro...

Страница 6: ...y 33 5 RAID 0 data striping S1 S4 of data blocks B1 B12 34 6 2 arrays A1 A2 and 5 logical drives L1 through L5 spread over 5 physical drives 36 7 Hardware RAID 42 8 Disk management partitioning ML110 G1 and DL100 45 9 ML110 G2 Express software RAID 47 10 ML110 G2 Workgroup hardware RAID 48 11 Disk management partitioning ML110 G2 Express 50 12 Disk management partitioning ML110 G2 Workgroup 52 13 ...

Страница 7: ... drive configuration 42 8 RAID configuration by hard drives 43 9 RAID configuration by logical drives 44 10 ML110 G2 Express Hard drive configuration 46 11 ML110 GS Workgroup Hard drive configuration 47 12 RAID configuration by hard drives 49 13 RAID configuration by logical drives 49 14 RAID configuration by hard drives 51 15 RAID configuration by logical drives 51 16 Hard drive configuration 53 ...

Страница 8: ...viii ...

Страница 9: ...nt Storage Server HP recommends that you obtain supplemental documentation relative to the items listed above in the section titled Intended Audience Related documentation In addition to this guide HP provides corresponding information HP ProLiant Storage Server Administration Guide HP ProLiant Storage Server Release Notes Conventions Conventions consist of the following Document conventions Text ...

Страница 10: ...and system responses output and messages Monospace italic font Command line and code variables Blue underlined text http www hp com Web site addresses Text symbols The following symbols may be found in the text of this guide They have the following meanings WARNING Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or death CAUTION Te...

Страница 11: ...y from electrical shock hazards do not open this enclosure WARNING Any RJ 45 receptacle marked with these symbols indicates a network interface connection WARNING To reduce the risk of electrical shock fire or damage to the equipment do not plug telephone or telecommunications connectors into this receptacle WARNING Any surface or area of the equipment marked with these symbols indicates the prese...

Страница 12: ...dling material Getting help If you still have a question after reading this guide contact an HP authorized service provider or access our web site http www hp com NOTE Known issues and workarounds for the storage server products and the service release are addressed in release notes To view the latest version visit http www hp com go support Select See support and troubleshooting information and e...

Страница 13: ...er SEA and OSEM are used both as part of the ISEE remote service offering and as standalone tools to HP service customers They are designed to send a notification only when an event or series of events has occurred that require service action They are not intended to be real time system state monitors that trigger with every event Most system components have the capability of sending hundreds of s...

Страница 14: ...he HP web site for locations and telephone numbers http www hp com Helpful web sites For third party product information see the following HP web sites http www hp com http www hp com go storage http www hp com support http www docs hp com 14 About this Guide ...

Страница 15: ...Use the Rapid Startup Wizard to complete the initial configuration See chapter 2 of this guide 5 Configure storage if applicable See chapter 3 of this guide for an overview of storage 6 Use the HP ProLiant Storage Server Administration Guide to complete any additional configuration tasks NOTE The latest Service Release kit is included with the Proliant Storage Server The Service Release DVD provid...

Страница 16: ...ormation is relevant to all storage servers Exceptions are noted throughout the text In addition see Tables 2 3 and 4 The following tables provide a quick reference for determining which sections of the storage server documentation apply to a particular model See the QuickSpecs for specific hardware and software information 16 Overview ...

Страница 17: ...ty This OS does not include support for Storage Resource Manager 2 0 file screening and quotas or print serving Also this OS does not allow Microsoft Exchange storage iSCSI Feature Pack HP OpenView Storage Mirroring anti virus backup or any other third party storage service applications to be loaded on the Storage Server bStorage Manager consists of Directory Quotas File Filtering and Storage Repo...

Страница 18: ...agera Yes Yes Yes Feature Pack support Yes Yes Yes Print services support Yes Yes Yes SAN support Yes Yes Yes Cluster support No No No iLO RILOE LO 100 Optional RILOE II iLO iLO NIC Portsb 1 1 1 aStorage Manager consists of Directory Quotas File Filtering and Storage Reports bMost servers support NIC teaming by default and include software support 18 Overview ...

Страница 19: ...s Yes Yes Yes Feature Pack support Yes No No No Print services support Yes Yes Yes Yes SAN support Yes Yes Yes Yes Cluster support No Yes Yes Yes iLO RILOE LO 100 iLO iLO iLO iLO NIC Portsb 1 2 2 2 aStorage Manager consists of Directory Quotas File Filtering and Storage Reports bMost servers support NIC teaming by default and include software support HP ProLiant Storage Server user guide 19 ...

Страница 20: ...20 Overview ...

Страница 21: ... com go support Select See support and troubleshooting information and enter a product name number Under self help resources select the manuals guides supplements addendums etc link Deploying the storage server on the network The default shipping configuration contains one or two 10 100 1000 integrated network interface controller NIC ports for client data access NIC data ports also allow access t...

Страница 22: ...er Table 5 Configuration Information Part A To be completed for DHCP and non DHCP configurations Server Host Name Part B To be completed for non DHCP configurations only DNS Servers IP Address 1 2 3 Storage Server NIC Port IP Address Subnet Mask Gateway Address NIC 1 NIC 2 Disable ports that will not be used Each Ethernet port whether standard or added must be configured with a separate subnet Par...

Страница 23: ... MUI Read Me First document 2 Before configuring the Proliant Storage Server insert the Service Release DVD into the DVD ROM drive on your Storage Server system 3 The installation should begin automatically If the setup does not begin automatically browse to the CD in Windows Explorer and double click on Setup exe 4 On the HP Storage Server Service Release menu click on Install Service Release X X...

Страница 24: ...he device is known it can be accessed through a client running Internet Explorer 5 5 or later on that network using the 3202 port of the device Requirements to run the WebUI configuration application Windows based PC loaded with Internet Explorer 5 5 or later on the same segment as the storage server DHCP enabled network Serial number of the storage server Procedure 1 Connect the Ethernet cable to...

Страница 25: ...is hpinvent The WebUI uses the same login as the local administrator s account or an account with administrative privileges 5 Go to Rapid Startup Wizard configuration to complete the setup procedures Method 2 Direct attach You can access the WebUI using a monitor mouse and keyboard directly attached to the storage server Procedure 1 Connect the Ethernet cable to the network port of the storage ser...

Страница 26: ...plication Rapid Startup on the target storage server as shown in Figure 1 If the WebUI does not launch connect to the LocalHost and login to the WebUI 6 Go to Rapid Startup Wizard configuration to complete the setup procedures Rapid Startup Wizard configuration This utility guides you through the configuration process Ensure that an Internet Explorer window is open and the WebUI is at the Rapid St...

Страница 27: ...Out iLO settings Procedure Using the information from Table 5 fill in the screens that follow 1 Click Next to start the Rapid Startup Wizard There may be a slight pause because the wizard is gathering information about the system and populating the fields 2 Configure the Date and Time Settings Click Next to continue 3 Configure the Administrator Account settings Click Next to continue 4 Configure ...

Страница 28: ...n is displayed as shown in Figure 2 Figure 2 Rapid Startup configuration review screen 9 Click Finish to exit Rapid Startup If a reboot is required Rapid Startup displays a message that a reboot is occurring and the configuration information will be set The browser returns to the status page The refresh can take several minutes if the device was restarted NOTE After the Rapid Startup Wizard is com...

Страница 29: ... shares corresponding to the protocols mentioned in the previous steps Configure shadow copies for creating point in time snapshots of data volumes Configure data replication software via Microsoft File Replication Services Enable and establish space usage quotas Configure DFS Distributed File System or publish the storage server shares into an already existing DFS structure Adjust logging for sys...

Страница 30: ...patches process on the storage server see Microsoft Software Updates on HP ProLiant Storage Servers at http h18006 www1 hp com storage storageservers html Configure UNIX user and group mappings Create and verify a full storage server system backup before putting the system into production Cluster setup If your storage server model supports clustering see the HP ProLiant Storage Server Administrati...

Страница 31: ...quirements that serve as the basis for successfully using an HP ProLiant Storage Server Failure to read this section and the appropriate sections on storage management in the administration guide may lead to data loss or file corruption Storage management elements Storage is divided into four major divisions Physical storage elements Logical storage elements File system elements File sharing eleme...

Страница 32: ... Sharing Elements CIFS and NFS File Shares Engineering Marketing Users Sales Engineering Marketing Users Sales Customers from 02 10 03 09 30 snapshot 0 from 02 10 03 11 30 snapshot 1 from 02 10 03 09 30 snapshot 0 from 02 10 03 11 30 snapshot 1 Q Q Q R R R R T S S U U Users VirtualServerA IP Addresss 172 1 1 1 VirtualServerA IP Addresss 172 1 1 2 Sales Marketing Engineering Snapshot 0 Snapshot 1 S...

Страница 33: ...hysical drives can be logically combined into one or more logical units called arrays When this is done the read write heads of all the constituent physical drives are active simultaneously dramatically reducing the overall time required for data transfer NOTE Depending on the storage server model array configuration may not be possible or necessary L1 P1 P2 P3 Figure 4 Configuring the physical dr...

Страница 34: ...e has a larger capacity than other hard drives in the same array the extra capacity is wasted because it cannot be used by the array Fault tolerance Drive failure although rare is potentially catastrophic For example in Figure 5 using simple striping failure of any hard drive leads to failure of all logical drives in the same array and hence to data loss To protect against data loss from hard driv...

Страница 35: ...cept RAID 0 This hard drive contains no data and is contained within the same storage sub system as the other drives in the array When a hard drive in the array fails the controller can then automatically rebuild information that was originally on the failed drive onto the online spare This quickly restores the system to full RAID level fault tolerance protection However unless RAID ADG is being u...

Страница 36: ...e physical storage elements into file system elements It is important to note that a LUN may extend over span all physical drives within a storage controller subsystem but cannot span multiple storage controller subsystems L4 L5 L3 A1 L1 L2 A2 Figure 6 2 arrays A1 A2 and 5 logical drives L1 through L5 spread over 5 physical drives NOTE This type of configuration may not apply to all storage server...

Страница 37: ...to no more than 32 separate LUNs with each LUN not exceeding 2 terabytes TB Volumes also cannot exceed 64 TB of disk space The RAID level of the LUNs included in a volume must be considered All of the units that make up a volume should have the same high availability characteristics In other words the units should all be of the same RAID level For example it would be a bad practice to include both...

Страница 38: ...rements increased within the allowable growth limits NOTE Dynamic disks cannot be used for clustering configurations because Microsoft Cluster only supports basic disks More detailed information regarding the WebUI for disk management activities can be found in the HP ProLiant Storage Server Administration Guide File System Elements File system elements are composed of the folders and subfolders t...

Страница 39: ...n help to simplify restore procedures For example shadow copies cannot protect against data loss due to media failures however recovering data from shadow copies can reduce the number of times needed to restore data from tape Detailed information on Shadow Copies can be found in the administration guide Utilizing Storage Elements No matter which type of storage element is created in the WebUI the ...

Страница 40: ...CAUTION AppleTalk shares should not be created on clustered resources as this is not supported by Microsoft Clustering and data loss may occur Network names and IP address resources for the clustered file share resource can also be established for access across a network to a variety of clients Permissions can then be granted to those shares based on users or groups of users in each of the file sh...

Страница 41: ...cally rebuild information that was originally on the failed drive onto the online spare This quickly restores the system to full RAID level fault tolerance protection However unless RAID ADG is being used which can support two drive failures in an array in the unlikely event that a third drive in the array should fail while data is being rewritten to the spare the logical drive will still fail NOT...

Страница 42: ...Logical Disk 1 Primary Operating System Disk RAID 1 Logical Disk 2 Secondary Operating System Disk RAID 1 Logical Disk 3 Data Volume RAID 5 Figure 7 Hardware RAID NOTE In Adaptec Storage Manager logical disks are labeled 1 2 and 3 In Disk Manager logical disks are displayed as 0 1 and 2 The primary OS logical drive resides on disk 0 and is mirrored on disk 1 while the secondary OS logical drive re...

Страница 43: ...ions The single RAID 5 disk houses the data volume on a basic partition Disk partitioning and RAID configuration ML110 G1 and DL100 The four hard drives included in the ML110 G1 and DL100 storage servers are configured for hardware RAID fault tolerance using the Adaptec 2410SA SATA RAID Controller The primary OS logical drive is configured as a 9 GB RAID 1 mirror spanning drives 0 and 1 The second...

Страница 44: ...nning physical drives 0 1 2 and 3 NOTE In Adaptec Storage Manager logical disks are labeled 1 2 and 3 In Disk Manager logical disks are displayed as 0 1 and 2 The default configuration for the data volume can be modified using the Disk Management utility Refer to the administration guide for additional information The BIOS supports the following default boot sequence 1 CD RW DVD ROM 2 HDD 0 1 2 NO...

Страница 45: ...t be restored from backup When the primary OS has a failure such as system files becoming corrupted registry corrupted and the system hangs during boot the system should be run from the secondary OS To run the system from the secondary OS 1 Power down the unit 2 Connect a monitor keyboard and mouse directly to the rear of the unit 3 Power on the unit 4 During boot up select to use the secondary pa...

Страница 46: ... hard drives are non hot pluggable The ProLiant ML110 G2 Workgroup Storage Server hard drives are hot pluggable ML110 G2 Express The drives are configured by default into three logical disks at the SATA controller level as follows Table 10 ML110 G2 Express Hard drive configuration Logical Disk RAID Size Allocation 1 RAID 1 9 GB across physical drive 0 1 2 RAID 1 9 GB across physical drive 1 0 3 RA...

Страница 47: ...lable for data backup prior to using the Quick Restore DVD to restore the system to the factory default state The data volume is configured as a software RAID 1 volume across both drives This ensures redundancy in the event of a drive failure The data volume is accessible by both the primary OS and secondary OS Refer to the administration guide for additional information ML110 G2 Workgroup The dri...

Страница 48: ... as a hardware RAID 5 based basic partition across all four drives This ensures redundancy in the event of a drive failure Refer to the administration guide for additional information Disk Manager The 100 series storage servers use Microsoft Disk Manager DM for managing the various types of disk presented to the file system Disk Manager has two types of disk presentations basic disk and dynamic di...

Страница 49: ...ion F User Data in RAID 1 Hard Drive 1 Partition C 9GB Backup OS Partition F User Data in RAID 1 Table 13 RAID configuration by logical drives Logical Drive 1 Partition C 9GB Primary OS RAID 1 Mirror across physical drives 0 and 1 Logical Drive 2 Partition E 9GB Backup OS RAID 1 Mirror across physical drives 1 and 0 Logical Drive 3 Partition F Data volume using remaining disk space RAID 1 mirror s...

Страница 50: ...ure such as system files becoming corrupted registry corrupted and the system hangs during boot the system should be run from the secondary OS To run the system from the secondary OS 1 Power down the unit 2 Connect a monitor keyboard and mouse directly to the rear of the unit 3 Power on the unit 4 During boot up select to use the secondary partition The user should backup their user data and then ...

Страница 51: ...rd Drive 2 Partition C 9GB OS Partition E User Data in RAID 5 Hard Drive 3 Partition C 9GB OS Partition E User Data in RAID 5 Table 15 RAID configuration by logical drives Logical Drive 1 Partition C 9GB Primary OS RAID 5 Mirror across physical drives 0 and 1 Logical Drive 2 Partition E 9GB Data volume using remaining disk space RAID 5 volume is striped across physical drives 0 1 2 and 3 NOTE In A...

Страница 52: ...nform the user of a drive failure If a single drive failure occurs it is transparent to the OS If a second drive fails the data volume is lost and must be restored from backup When the primary OS has a failure such as system files becoming corrupted registry corrupted and the system hangs during boot the system should be restored to the factory default state using the Quick Restore DVD The user sh...

Страница 53: ...e HP Array Configuration Utility Adaptec Storage Manager or SAN management tools Physical drive configuration Each 300 series and 500 series storage server comes with two hot pluggable hard drives for the Operating System only The drives are configured by default into two logical disks at the controller level as follows Table 16 Hard drive configuration Logical Disk RAID Size Allocation 1 RAID 1 2...

Страница 54: ...n the HP Array Configuration Utility and Adaptec Storage Manager logical disks are labeled 1 and 2 In Disk Manager logical disks are displayed as 0 and 1 Data volumes are not carved at the factory nor by the Quick Restore DVD and must be configured manually by the end user Refer to the HP ProLiant Storage Server Administration Guide for additional information 54 Server Storage ...

Страница 55: ...ch class A or B the equipment falls into Class B devices have an FCC logo or FCC ID on the label Class A devices do not have an FCC logo or FCC ID on the label Once the class of the device is determined refer to the following corresponding statement Class A equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules...

Страница 56: ...lt the dealer or an experienced radio or television technician for help Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett Packard Company may void the user s authority to operate the equipment Cables Connections to this device must be made with shielded cables with metallic RFI EMI connector hoods...

Страница 57: ...u Canada Class B equipment This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada European Union Notice Products bearing the CE marking comply with the EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC issued ...

Страница 58: ...C61000 4 2 3 4 5 6 8 11 Electromagnetic Immunity EN61000 3 2 IEC61000 3 2 Power Line Harmonics EN61000 3 3 IEC61000 3 3 Power Line Flicker EN 60950 IEC 60950 Product Safety BSMI Notice Japanese Notice Japanese Power Cord Notice 58 Regulatory Compliance Notices ...

Страница 59: ...ase use the public collection system or return them to HP an authorized HP Partner or their agents For more information about battery replacement or proper disposal contact an authorized reseller or an authorized service provider Taiwan Battery Recycling Notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate t...

Страница 60: ...ur bij een inzamelingspunt voor het recyclen van oude elektrische en elektronische apparatuur Door uw oude apparatuur apart aan te bieden en te recyclen kunnen natuurlijke bronnen worden behouden en kan het materiaal worden hergebruikt op een manier waarmee de volksgezondheid en het milieu worden beschermd Neem contact op met uw gemeente het afvalinzamelingsbedrijf of de winkel waar u het product ...

Страница 61: ...tmed ringlussevõtmiseks viia võtke palun ühendust oma kohaliku linnakantselei majapidamisjäätmete kõrvaldamise teenistuse või kauplusega kust Te toote ostsite Finnish notice Laitteiden hävittäminen kotitalouksissa Euroopan unionin alueella Jos tuotteessa tai sen pakkauksessa on tämä merkki tuotetta ei saa hävittää kotitalousjätteiden mukana Tällöin hävitettävä laite on toimitettava sähkölaitteiden...

Страница 62: ...acheté ce produit German notice Entsorgung von Altgeräten aus privaten Haushalten in der EU Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin dass das Produkt nicht über den normalen Hausmüll entsorgt werden darf Benutzer sind verpflichtet die Altgeräte an einer Rücknahmestelle für Elektro und Elektronik Altgeräte abzugeben Die getrennte Sammlung und ordnungsgemäße Entsorgung Ihre...

Страница 63: ...a készülék a selejtezés során az egyéb háztartási hulladéktól eltérő módon kezelendő A vásárló a hulladékká vált készüléket köteles a kijelölt gyűjtőhelyre szállítani az elektromos és elektronikai készülékek újrahasznosítása céljából A hulladékká vált készülékek selejtezéskori begyűjtése és újrahasznosítása hozzájárul a természeti erőforrások megőrzéséhez valamint biztosítja a selejtezett termékek...

Страница 64: ... saglabāt dabas resursus un garantēs ka šīs iekārtas tiks otrreizēji pārstrādātas tādā veidā lai pasargātu vidi un cilvēku veselību Lai uzzinātu kur nolietotās iekārtas var izmest otrreizējai pārstrādei jāvēršas savas dzīves vietas pašvaldībā sadzīves atkritumu savākšanas dienestā vai veikalā kurā izstrādājums tika nopirkts Lithuanian notice Vartotojų iš privačių namų ūkių įrangos atliekų šalinima...

Страница 65: ...asta zakładem gospodarki odpadami lub sklepem w którym zakupiono produkt Portuguese notice Descarte de Lixo Elétrico na Comunidade Européia Este símbolo encontrado no produto ou na embalagem indica que o produto não deve ser descartado no lixo doméstico comum É responsabilidade do cliente descartar o material usado lixo elétrico encaminhando o para um ponto de coleta para reciclagem A coleta e a r...

Страница 66: ... izdelka ne smete odvreči med gospodinjske odpadke Nasprotno odsluženo opremo morate predati na zbirališče pooblaščeno za recikliranje odslužene električne in elektronske opreme Ločeno zbiranje in recikliranje odslužene opreme prispeva k ohranjanju naravnih virov in zagotavlja recikliranje te opreme na zdravju in okolju neškodljiv način Za podrobnejše informacije o tem kam lahko odpeljete odslužen...

Страница 67: ...ll inom Europeiska Unionen Om den här symbolen visas på produkten eller förpackningen betyder det att produkten inte får slängas på samma ställe som hushållssopor I stället är det ditt ansvar att bortskaffa avfallet genom att överlämna det till ett uppsamlingsställe avsett för återvinning av avfall från elektriska och elektroniska produkter Separat insamling och återvinning av avfallet hjälper til...

Страница 68: ...68 Regulatory Compliance Notices ...

Страница 69: ...be properly grounded when touching a static sensitive component or assembly Grounding methods There are several methods for grounding Use one or more of the following methods when handling or installing electrostatic sensitive parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resis...

Страница 70: ...NOTE For more information on static electricity or for assistance with product installation contact your authorized reseller 70 Electrostatic Discharge ...

Страница 71: ...l disks 29 volume 29 D data blocks 34 data replication 29 data striping 33 default login 25 26 default page 27 deployment on network 21 DHCP dynamic host configuration protocol defined 22 disk management 52 52 Distributed File System 29 DM Disk Manager 38 39 document conventions 10 prerequisites 9 related documentation 9 9 dynamic disks 38 converting 37 dynamic host configuration protocol See DHCP...

Страница 72: ...oyment 21 network interface information configuring 28 O online spares 35 P partitioning 52 52 partitions 38 extended 37 primary 37 physical storage elements 32 prerequisites 9 Q quotas 29 R rack stability warning 11 RAID RAID 0 33 summary of methods 35 Rapid Startup configuration review screen illustrated 28 using 26 wizard screen illustrated 27 related documentation 9 9 requirements IP networkin...

Страница 73: ... text symbols 10 V volumes planning 37 W warning rack stability 11 WebUI accessing 23 elements required to run 24 WebUI configuration 23 direct attach method 25 Remote Browser method 24 HP ProLiant Storage Server user guide 73 ...