![background image](http://html.mh-extra.com/html/hp/proliant-dl560-gen10/proliant-dl560-gen10_maintenance-and-service-manual_164779083.webp)
Systems Insight Display
LED and color
Health
LED
System
power LED
Status
Processor (amber)
Red
Amber
One or more of the following
conditions may exist:
• Processor in socket X has failed.
• Processor X is not installed in the
socket.
• Processor X is unsupported.
• ROM detects a failed processor
during POST.
Processor (amber)
Amber
Green
Processor in socket X is in a pre-
failure condition.
DIMM (amber)
Red
Green
One or more DIMMs have failed.
DIMM (amber)
Amber
Green
DIMM in slot X is in a pre-failure
condition.
Over temp (amber)
Amber
Green
The Health Driver has detected a
cautionary temperature level.
Over temp (amber)
Red
Amber
The server has detected a hardware
critical temperature level.
PCI riser (amber)
Red
Green
The PCI riser cage is not seated
properly.
Fan (amber)
Amber
Green
One fan has failed or has been
removed.
Fan (amber)
Red
Green
Two or more fans have failed or been
removed.
Power supply (amber)
Red
Amber
One or more of the following
conditions may exist:
• Only one power supply is installed
and that power supply is in
standby.
• Power supply fault
• System board fault
Table Continued
Component identification
83
Содержание ProLiant DL560 Gen10
Страница 6: ...Warranty information 124 Regulatory information 125 Documentation feedback 125 6 Contents ...
Страница 27: ...Customer self repair 27 ...
Страница 28: ...28 Customer self repair ...
Страница 29: ...Customer self repair 29 ...
Страница 30: ...30 Customer self repair ...
Страница 79: ...Eight bay SFF NVMe drive cage Two bay NVMe Six bay SFF HDD drive cage Component identification 79 ...
Страница 102: ...16 SFF backplanes Group C SAS cables 102 Cabling ...
Страница 104: ...Connected to the secondary PCIe riser board Connected to the tertiary PCIe riser board 104 Cabling ...
Страница 105: ...Connected to the system board SATA ports 1 and 2 Connected to the HPE P816i a Smart Array controller Cabling 105 ...
Страница 107: ...Connected to the secondary PCIe riser board Connected to the tertiary PCIe riser board Cabling 107 ...
Страница 108: ...Connected to the system board SATA ports 1 and 2 Connected to the Smart Array controller 108 Cabling ...
Страница 109: ...Drive box 3 cabling Connected to the Primary PCIe riser board Connected to the secondary PCIe riser board Cabling 109 ...
Страница 110: ...Connected to the system board SATA ports 1 and 2 Connected to an HPE Smart Array controller 110 Cabling ...
Страница 113: ...Quad slimline riser installed in the secondary PCIe riser cage Tertiary riser Cabling 113 ...