Component identification 11
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing a health
event. Combinations of illuminated Systems Insight Display LEDs, the system power LED, and the health LED
indicate system status.
Systems Insight Display
LED and color
Health LED
System power
LED
Status
Processor (amber)
Red
Amber
One or more of the following conditions may
exist:
•
Processor in socket
X
has failed.
•
Processor
X
is not installed in the socket.
•
Processor
X
is unsupported.
•
ROM detects a failed processor during
POST.
Processor (amber)
Amber
Green
Processor in socket
X
is in a pre-failure
condition.
DIMM (amber)
Red
Green
One or more DIMMs have failed.
DIMM (amber)
Amber
Green
DIMM in slot
X
is in a pre-failure condition.
Over temp (amber)
Amber
Green
The Health Driver has detected a cautionary
temperature level.
Over temp (amber)
Red
Amber
The server has detected a hardware critical
temperature level.
PCI riser (amber)
Red
Green
The PCI riser cage is not seated properly.
Fan (amber)
Amber
Green
One fan has failed or has been removed.
Fan (amber)
Red
Green
Two or more fans have failed or been
removed.
Power supply (amber)
Red
Amber
One or more of the following conditions may
exist:
•
Only one power supply is installed and
that power supply is in standby.
•
Power supply fault
•
System board fault
Power supply (amber)
Amber
Green
One or more of the following conditions may
exist:
•
Redundant power supply is installed and
only one power supply is functional.
•
AC power cord is not plugged into
redundant power supply.
•
Redundant power supply fault
•
Power supply mismatch at POST or
power supply mismatch through hot-plug
addition
Power cap (off)
—
Amber
Standby
Power cap (green)
—
Flashing green
Waiting for power
Power cap (green)
—
Green
Power is available.
IMPORTANT:
If more than one DIMM slot LED is illuminated, further troubleshooting is required.
Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing
each DIMM in a bank with a known working DIMM.
Содержание ProLiant DL388p
Страница 44: ...Hardware options installation 44 14 Install the heatsink 15 Remove the two fan blanks ...
Страница 82: ...Cabling 82 Cabling SAS hard drive cabling SFF hard drive cabling SFF cabling with optional drive cage ...
Страница 83: ...Cabling 83 LFF hard drive cabling Optical drive cabling ...
Страница 84: ...Cabling 84 FBWC cabling 8 or 16 drive SFF 8 drive LFF PCIe option ...
Страница 120: ...Technical support 120 ...