Operations 22
2.
Push down on the hood latch. The access panel slides to a closed position.
3.
Use the T-15 Torx screwdriver provided with the server to tighten the security screw on the hood latch.
Remove the air baffle
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
1.
Power down the server (on page
18
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
18
).
o
Remove the server from the rack (on page
20
).
4.
Remove the access panel (on page
21
).
5.
Remove the air baffle.
Install the air baffle
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
Содержание ProLiant DL388e
Страница 82: ...Cabling 82 Cabling Storage cabling 4 drive LFF SATA cabling Mini SAS cable Power cable ...
Страница 83: ...Cabling 83 4 drive SFF SATA cabling Mini SAS cable Power cable ...
Страница 84: ...Cabling 84 6 drive LFF SATA cabling Mini SAS cable 1 and two port SATA cable 2 Power cable ...
Страница 86: ...Cabling 86 o Mini SAS cables connected to a riser board with SAS support o Smart Array cables Power cable ...
Страница 93: ...Cabling 93 Sideband signal 1 and SATA 2 cables connected to the expander backplane Power cables ...
Страница 97: ...Cabling 97 o Secondary GPU power cabling ...
Страница 131: ...Support and other resources 131 ...