Removal and replacement procedures 37
NOTE:
If using the power cord anchor, be sure to leave enough slack in the power cord so that
the redundant power supply can be removed without disconnecting the power cord from the
primary power supply.
5.
Close the cable management arm.
6.
Connect the power cord to the power source.
7.
Be sure that the power supply LED is green ("
" on page
8.
Be sure that the power supply LED on the SID is green ("
" on page
Optical drive
To remove the component:
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
1.
Power down the server (on page
2.
Extend or remove the server from the rack ("
Remove the server from the rack
" on page
" on page
3.
Remove the access panel ("
" on page
4.
Disconnect the cable from the optical drive.