Removal and replacement procedures 27
NOTE:
If the operating system automatically places the server in Standby mode, omit the next
step.
3.
Press the Power On/Standby button to place the server in Standby mode. When the server activates
Standby power mode, the system power LED changes to amber.
IMPORTANT:
Pressing the UID button illuminates the blue UID LEDs on the front and rear panels.
In a rack environment, this feature facilitates locating a server when moving between the front and
rear of the rack.
4.
Disconnect the power cords.
The system is now without power.
Extend the server from the rack
1.
Pull down the quick release levers on each side of the server.
2.
Extend the server from the rack.
WARNING:
To reduce the risk of personal injury or equipment damage, be sure that the rack is
adequately stabilized before extending a component from the rack.
3.
After performing the installation or maintenance procedure, slide the server back into the rack, and then
press the server firmly into the rack to secure it in place.
WARNING:
To reduce the risk of personal injury, be careful when pressing the server rail-release
latches and sliding the server into the rack. The sliding rails could pinch your fingers.
Содержание ProLiant DL380 G7
Страница 5: ...Contents 5 Index 110 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...Customer self repair 16 ...
Страница 20: ...Illustrated parts catalog 20 System components ...
Страница 63: ...Removal and replacement procedures 63 6 Open the heatsink retaining bracket 7 Remove the heatsink ...
Страница 82: ...Cabling 82 Cabling SAS hard drive cabling Optical drive cabling ...
Страница 83: ...Cabling 83 BBWC battery cabling FBWC capacitor pack cabling ...