Removal and replacement procedures 52
5.
Disconnect the cable, and then remove the battery pack.
To replace the component, reverse the removal procedure.
Recovering data from the battery-backed write cache
If the server fails, use the following procedure to recover data temporarily stored in the BBWC.
CAUTION:
Before starting this procedure, read the information about protecting against
electrostatic discharge ("
Preventing electrostatic discharge
" on page
1.
Perform one of the following:
o
Set up a recovery server station using an identical server model. Do not install any internal drives or
BBWC in this server. (HP recommends this option.)
o
Find a server that has enough empty drive bays to accommodate all the drives from the failed server
and that meets all the other requirements for drive and array migration.
2.
Power down the failed server ("
" on page
). If any data is stored in the cache
module, a green LED on the module flashes every 2 seconds.
CAUTION:
Do not detach the cable that connects the battery pack to the cache module.
Detaching the cable causes any unsaved data in the cache module to be lost.
3.
Transfer the hard drives from the failed server to the recovery server station.
4.
Perform one of the following:
o
If the array controller has failed, remove the cache module ("
" on page
" on page
) from the failed array controller,
and install the cache module and battery pack on an array controller in the recovery server.
o
If the server has failed, remove the controller ("
" on page
" on page
" on page
) from the failed server, and install
the controller, cache module, and battery pack in the recovery server.
Содержание ProLiant DL380 G7
Страница 5: ...Contents 5 Index 110 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...Customer self repair 16 ...
Страница 20: ...Illustrated parts catalog 20 System components ...
Страница 63: ...Removal and replacement procedures 63 6 Open the heatsink retaining bracket 7 Remove the heatsink ...
Страница 82: ...Cabling 82 Cabling SAS hard drive cabling Optical drive cabling ...
Страница 83: ...Cabling 83 BBWC battery cabling FBWC capacitor pack cabling ...