System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
1.70 x 16.78 x 27.75 in (4.32 x 42.62 x 70.49 cm)
Weight
Weight
Weight
Weight
Maximum (six hard drives
installed, two power
supply, two processor)
37 lb (16.78 kg)
No hard drives installed,
one power supply, one
processor
27.5 lb (12.47 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
Rated Input Voltage
100 to 240 VAC
Rated Input Current
7.1 Amps (at 120VAC) to 3.5 Amps (240 at
VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
852 W
BTU Rating
BTU Rating
BTU Rating
BTU Rating
2910 BTU/HR (at 120 VAC); 2870 (at 240 VAC)
NOTE:
NOTE:
NOTE:
NOTE: The BTU rating listed is for the Rated Input Power of 585 W.
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc
/Power%20Calculator%20Catalog.xls
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL365
- Click on: "Power Calculator" link. (You may need to scroll down to see it)
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power
(per power supply)
Rated Steady-State Power 700 W
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Storage
-30° to 60°C - Maximum rate of change is
20°C/Hr.
Humidity
Humidity
Humidity
Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C maximum
wet bulb temperature
Storage
5 to 95% relative humidity (Rh), 38.7°C
maximum wet bulb temperature.
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
QuickSpecs
HP ProLiant DL365
HP ProLiant DL365
HP ProLiant DL365
HP ProLiant DL365
Technical Specifications
DA - 12564 Worldwide — Version 31 — September 15, 2008
Page 40