Removal and replacement procedures 89
To reinstall the non-hot-plug power supply:
1.
Locate and push the power supply to the proper place in the chassis.
2.
Fasten the power supply to the chassis using the screws as shown in the figure below.
Figure 84
Reinstalling the Non-hot-plug Power Supply
3.
Fasten the two screws which are located beneath the chassis to secure the power supply
Figure 85
Fastening the Two Screws beneath the Chassis
WARNING:
Take note of the following reminders to reduce the risk of personal injury from electric
shock hazards and/or damage to the equipment.
•
Installation of power supply units should be referred to individuals who are qualified to service
server systems and are trained to deal with equipment capability of generating hazardous
energy levels.
•
DO
not
open the power supply unit. There are no serviceable parts inside it.