Figure 14 SAS/SATA hard drive LEDs
Table 17 SAS and SATA hard drive LED combinations
Status
2. Online/activity LED
(green)
1. Fault/UID LED
(amber/blue)
The drive has failed, or a predictive failure alert has
been received for this drive; it also has been selected
by a management application.
On, off, or flashing
Alternating amber and blue
The drive is operating normally, and it has been
selected by a management application.
On, off, or flashing
Steadily blue
A predictive failure alert has been received for this
drive. Replace the drive as soon as possible.
On
Amber, flashing regularly (1
Hz)
The drive is online, but it is not active currently.
On
Off
Do not remove the drive. Removing a drive may
terminate the current operation and cause data loss.
The drive is part of an array that is undergoing
capacity expansion or stripe migration, but a
predictive failure alert has been received for this
drive. To minimize the risk of data loss, do not
replace the drive until the expansion or migration is
complete.
Flashing regularly (1 Hz)
Amber, flashing regularly (1
Hz)
Do not remove the drive. Removing a drive may
terminate the current operation and cause data loss.
The drive is rebuilding, or it is part of an array that
is undergoing capacity expansion or stripe
migration.
Flashing regularly (1 Hz)
Off
The drive is active, but a predictive failure alert has
been received for this drive. Replace the drive as
soon as possible.
Flashing irregularly
Amber, flashing regularly (1
Hz)
The drive is active, and it is operating normally.
Flashing irregularly
Off
A critical fault condition has been identified for this
drive, and the controller has placed it offline.
Replace the drive as soon as possible.
Off
Steadily amber
HP ProLiant Storage Server
49
Содержание PROLIANT DL160 G5
Страница 1: ...HP ProLiant Storage Server user guide Part number 440584 005 First edition June 2008 ...
Страница 34: ...Installing and configuring the server 34 ...
Страница 52: ...Server components 52 ...
Страница 94: ...File server management 94 ...
Страница 112: ...Microsoft Services for Network File System MSNFS 112 ...
Страница 152: ...Troubleshooting servicing and maintenance 152 ...
Страница 154: ...System recovery 154 ...
Страница 160: ...BSMI notice Japanese notice Korean notice A B Class A equipment Class B equipment Regulatory compliance and safety 160 ...
Страница 174: ...Index 174 ...