Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure,
and the same operating guidelines listed above will still apply.
Temperature Range
Operating: 50° to 95° F (10° to 35° C)
*
Non-operating: –22° to 140° F(–30° to 60° C)
Relative Humidity
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum Altitude
(unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight.
Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Standard Efficiency
180W active PFC (230 VAC input only)
180W Reg (115V/230Vac)
High Efficiency*
80 PLUS Bronze
180W active PFC EStar 6
82/85/82% efficient at 20/50/100% load (115V)
82/85/82% efficient at 20/50/100% load (230V)
Operating Voltage Range
90 – 264 VAC
Rated Voltage Range
200 – 240 VAC (180W active PFC)
100 – 240 VAC (180W EStar 6)
115VAC/230VAC (180W Reg)
Rated Line Frequency
50/60 Hz
Operating Line Frequency Range
47 – 63 Hz
Rated Input Current
4A/200VAC, 8A/100VAC
Rated Input Current with Energy Efficient
*
Power Supply
6.3A/100VAC
Current Leakage
(NFPA 99)
<900uA / 230Vac
Current Leakage with Energy Efficient *Power Supply
<600uA/230VAC
Power Supply Fan
80mm Fan
Power cord length
6.0 ft. (1.83 m)
External Power Adapter
Dimensions
N/A
QuickSpecs
HP ProDesk 405 G2 Microtower Business PC
Technical Specifications – Power
DA - 14983 North America — Version 1 — May 28, 2014
Page 51