178
Software Fixes in Release M.08.51 - M.10.72
Release M.10.66
■
Authentication (PR_1000454714)
— Concurrent 802.1X and MAC Authentication does
not give the 802.1X value precedence. This fix gives 802.1X VLAN assignment precedence
over MAC Auth RADIUS VLAN assignment.
■
Web Management (PR_1000760153)
— A Java error occurs when viewing "Stack
Closeup" in the Web Management interface. Only a blank screen is displayed.
■
DHCP Snooping (PR_1000469934)
— When DHCP Snooping is enabled and configured,
and a client sends a “DHCPINFORM” after receiving address information, the DHCP server
response is not forwarded to the client by the switch.
■
IDM/DIPLD (PR_1000784427)
— The IDM feature that allows RADIUS-assigned ACLs for
802.1X clients was incorrectly enabled to support DIPLD CLI commands.
■
RADIUS/Jumbo (PR_ 1000779048)
— When an 802.1X enabled port belongs to a VLAN
that is jumbo enabled, the Access-Request will specify a value of Framed-MTU of 9182 bytes.
When the RADIUS server replies with a large frame, the switch does not respond, causing
the authentication process to halt.
■
Crash (PR_0000001756)
— Some SNMP set commands may cause the switch to crash
with a message similar to the following.
Software exception at bcmHwVlans.c:149 -- in 'mAdMgrCtrl', task
ID=0x18636e8 -> ASIC call failed: Entry not found.
■
Crash (PR_0000002433)
— A certain sequence of CLI commands may cause the switch
to crash with a message similar to the following.
Software exception at dsnoop_ctrl.c:109 -- in 'mDsnoop002'.
■
Enhancement (PR_0000001316)
— The MSTP VLAN Assignment is enhanced. For more
information, see
“Release M.10.65 Enhancements” on page 136
.
■
Config (PR_0000002077)
— Upload of configuration files fails when the spanning-tree CLI
command is present in the config file.
■
VLAN (PR_0000002103)
— The alteration of the VLAN/MSTP instance mapping in the
pending configuration is not functioning properly. Any attempt to remove a single VLAN ID
(VID) from one MSTP instance and then assign it to another MSTP instance fails, though
specifying a VID range succeeds.
Release M.10.66
Problems Resolved in Release M.10.66
(Not a Public Release)
■
UDLD (PR_0000002473)
— UDLD protocol packets received on a (non-UDLD) trunk port
are incorrectly forwarded out of the same port from which they are received, resulting in
high CPU usage on the switch.