Port Status and Basic Configuration
Viewing Port Status and Configuring Port Parameters
Table 10-1. Cable Types for Auto and Manual MDI/MDI-X Settings
MDI/MDI-X Device Type
Setting
PC or Other MDI Device Type
Switch, Hub, or Other MDI-X Device
Manual MDI
Crossover Cable
Straight-Through Cable
Manual MDI-X
Straight-Through Cable
Crossover Cable
Auto-MDI-X
(The Default)
Either Crossover or Straight-Through Cable
The Auto-MDIX features apply only to copper port switches using twisted-pair
copper Ethernet cables.
Syntax:
interface <
port-list
> mdix-mode < automdix | mdi | mdix >
automdix
is the automatic, default setting. This configures the
port for automatic detection of the cable (either straight-through
or crossover).
mdi
is the manual mode setting that configures the port for
connecting to either a PC or other MDI device with a crossover
cable, or to a switch, hub, or other MDI-X device with a straight-
through cable.
mdix
is the manual mode setting that configures the port for
connecting to either a switch, hub, or other MDI-X device with
a crossover cable, or to a PC or other MDI device with a straight-
through cable.
Syntax:
show interfaces config
Lists the current per-port Auto/MDI/MDI-X configuration.
Syntax:
show interfaces brief
Where a port is linked to another device, this command lists the
MDI mode the port is currently using. In the case of ports
configured for
Auto
(
auto-mdix
),
the MDI mode appears as either
MDI
or
MDIX
, depending upon which option the port has
negotiated with the device on the other end of the link. In the
case of ports configured for
MDI
or
MDIX
, the mode listed in this
display matches the configured setting. If the link to another
device was up, but has gone down, this command shows the last
operating MDI mode the port was using. If a port on a given
switch has not detected a link to another device since the last
reboot, this command lists the MDI mode to which the port is
currently configured.
For example,
show interfaces config
displays the following data when port 1 is
configured for
auto-mdix
, port 2 is configured for
mdi
, and port 3 is configured
for
mdix
.
10-13
Содержание ProCurve Series 2810
Страница 1: ...Management and Configuration Guide 2810 www procurve com ProCurve Series 2810 Switches N 10 XX ...
Страница 2: ......
Страница 3: ...ProCurve Series 2810 Switches July 2006 Management and Configuration Guide ...
Страница 56: ...Using the Menu Interface Where To Go From Here This page is intentionally unused 3 16 ...
Страница 98: ...Using the Web Browser Interface Status Reporting Features This page is intentionally unused 5 26 ...
Страница 240: ...Port Trunking Port Status and Configuration This page is intentionally unused 11 26 ...
Страница 320: ...File Transfers Copying Diagnostic Data to a Remote Host PC or Unix Workstation This page is intentionally unused A 24 ...
Страница 350: ...Monitoring and Analyzing Switch Operation Locating a Device This page is intentionally unused B 30 ...
Страница 404: ...MAC Address Management Viewing the MAC Addresses of Connected Devices This page is intentionally blank D 8 ...
Страница 408: ...Daylight Savings Time on ProCurve Switches Configuring Daylight Savings Time This page is intentionally unused E 4 ...
Страница 419: ... This page is intentionally unused ...