![HP procurve radio port 220 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/hp/procurve-radio-port-220/procurve-radio-port-220_installation-and-getting-started-manual_162872013.webp)
13
Installation Instructions
Suspended Ceiling Tile (Plenum) Mount
Mounting the Radio Port 220 above a suspended ceiling (in the plenum)
consists of placing the ProCurve Radio Port 220 above a suspended ceiling
and making the appropriate safety wire, antenna, and Ethernet connections.
If desired, the light pipe extender provided with the Radio Port can be used
to make the Radio Port's location and status visible from below the suspended
ceiling. The procedure below outlines the installation using the light pipe
extender
W A R N I N G
Do not mount the ProCurve Radio Port 220 directly to any suspended
ceiling tile with a thickness less than 12.7mm (0.5in.) or a suspended
ceiling tile with an unsupported span greater than 660mm (26in.).
The Radio Port 220 case is equipped with a safety wire tie point. To
prevent accidental damage or injury, HP strongly recommends that
installers secure the ProCurve Radio Port 220 with a safety wire
suitable for the specific installation. The safety wire should be a
standard ceiling suspension cable or equivalent steel wire between
1.59mm (.062in.) and 2.5mm (.10in.) in diameter.
Alignment Arrows