Chapter 3
Hardware Installation and Configuration
1. Locate the 50-pin connector on the HP Server Remote Management Card.
Figure 3-1: Locating the 50-pin Connector
2. Plug the end of the 50-pin ribbon that is labeled “To Card” into the card’s
connector.
3. If additional cable is needed, order HP Part Number P3537-63010.
NOTE
The ribbon cable is keyed to prevent incorrect cable
connection.
Installing the HP Server Remote Management
Card in the Server
Install the HP Server Remote Management Card into slot 6 on your server’s
system board. For specific information about installing a PCI card in your server,
refer to the
Operations and Maintenance Guide
supplied with your server. See
Appendix D, "Technical Specifications," for information about the power
requirements for the HP Server Remote Management Card.
WARNINGS
1.
Power down your Server and unplug all connecting cables
before installing your Management Card.
Always
disconnect AC power and unplug external connecting
cables from HP Servers before working inside the unit.
Hazardous voltages are present inside the Server that may
persist until the power cords are unplugged, even after the
16