Wall or Under-table Mounting:
To mount the
1920S-24G, 1920S-24G-PPoE+, 1920S-24G-PoE
+, 1920S-48G, and 1920S-48G-PPoE+ switches:
• First attach the mounting brackets to the switch
by using the included 8-mm M4 screws with a
#1 Phillips (cross-head) screwdriver.
• Then attach the switch to the wall or wood
surface with two 5/8-inch number 12 wood
screws (not included).
To mount the 1920S-8G and 1920S-8G-PPoE+
switches:
• First, mark the position for the mounting screws.
The hole-to-hole distance is 3.54 inch (90-mm).
• Then, use a #1 Phillips (cross-head)
screwdriver and two of the included 20-mm 4
tap screws. Set the screw heads approximately
2 mm away from the mounting surface to allow
the switch to slide on to the screws. Wall
anchors are included in the accessory kit for
use with plastered brick or concrete walls.
• For an under-table mounting, a third 20-mm M4
tap screw can be placed against one side of the
switch to secure it in place.
IMPORTANT:
Wall-mount the switch with network ports
facing up or down (away from or toward the
floor). Do not wall-mount the switch with the
ventilation holes facing up or down. (See
Installation Precautions
.)
5. Power on the switch.
Follow the same procedures as in step 3.
6. Configure the switch for operation on your network (minimal configuration).
6
HPE OfficeConnect 1920S Switch Series