Troubleshooting
7
Troubleshooting
These procedures are intended to be used only during initial configuration, for the purpose of verifying that hardware
setup is successful. They are not intended to be used as troubleshooting procedures for configured systems using
production data and I/O.
USB CLI port connection
MSA 2050 controllers feature a CLI port employing a mini-USB Type B form factor. If you encounter problems
communicating with the port after cabling your computer to the USB device, you may need to either download a device
driver (Windows), or set appropriate parameters via an operating system command (Linux). See
controller CLI port” (page 37)
for more information.
Fault isolation methodology
MSA 2050 controllers provide many ways to isolate faults. This section presents the basic methodology used to locate
faults within a storage system, and to identify the associated Field Replaceable Units (FRUs) affected.
, use the SMU to configure and provision the system upon completing the
hardware installation. As part of this process, configure and enable event notification so the system will notify you when
a problem occurs that is at or above the configured severity (see “Using the Configuration Wizard > Configuring event
notification” within the SMU Reference Guide). With event notification configured and enabled, you can follow the
recommended actions in the notification message to resolve the problem, as further discussed in the options presented
below.
Basic steps
The basic fault isolation steps are listed below:
•
Gather fault information, including using system LEDs [see
“Gather fault information” (page 45)
].
•
Determine where in the system the fault is occurring [see
“Determine where the fault is occurring” (page 45)
•
Review event logs [see
“Review the event logs” (page 45)
•
If required, isolate the fault to a data path component or configuration [see
].
Cabling systems to enable use of the licensed Remote Snap feature—to replicate volumes—is another important fault
isolation consideration pertaining to initial system installation. See
“Isolating Remote Snap replication faults” (page 53)
for more information about troubleshooting during initial setup.
Options available for performing basic steps
When performing fault isolation and troubleshooting steps, select the option or options that best suit your site
environment. Use of any option (four options are described below) is not mutually-exclusive to the use of another option.
You can use the SMU to check the health icons/values for the system and its components to ensure that everything is
okay, or to drill down to a problem component. If you discover a problem, both the SMU and the CLI provide
recommended-action text online. Options for performing basic steps are listed according to frequency of use:
•
Use the SMU.
•
Use the CLI.
•
Monitor event notification.
•
View the enclosure LEDs.
Use the SMU
The SMU uses health icons to show OK, Degraded, Fault, or Unknown status for the system and its components. The
SMU enables you to monitor the health of the system and its components. If any component has a problem, the system
health will be Degraded, Fault, or Unknown. Use the SMU to drill down to find each component that has a problem, and
follow actions in the Recommendation field for the component to resolve the problem.