![HP Model 712/100 - Workstation Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/hp/model-712-100-workstation/model-712-100-workstation_handbook_156870054.webp)
3–14
Configuration
Memory
The system has two pairs of memory connectors, labeled Slot 0 and Slot 1 for Pair 0,
and Slot 2 and Slot 3 for Pair 1, as shown in Figure 3–13. The model 712/100 has a
third pair of connectors labeled Slot 4 and Slot 5, as shown in Figure 3–14. Install
memory boards according to the following guidelines:
Install memory boards in pairs of the same memory capacity.
Board Pair 0 may have a different memory capacity than Board Pair 1. For
example, if the Pair 0 has 16–MB memory boards, Pair 1 may have 4–MB
memory boards. Always put the largest capacity memory boards in the
lowest numbered slots.
Install the first pair of memory boards in the connectors labeled 0 and 1
(Pair 0) and the second pair, which is optional, in the connectors labeled 2
and 3 (Pair 1). In the 712/100 add the third pair in the connectors labeled 4
and 5 (Pair 2).
Back of
System
Unit
Pair 0
0
1
2
3
Pair 1
Figure 3–13. Memory Connectors