Troubleshooting
267
Audible Beeps: None
Possible Cause: External and internal connectors of the specified SCSI ports are
connected to drives. The indicated SCSI bus is disabled until this problem is
resolved.
Action: The SCSI bus is not properly terminated when internal and external
drives are connected concurrently to the same SCSI bus.
1.
27
Power down the server ("Powering down the server" on page
).
2. Be sure the cables to the specified port are connected properly and securely
("Loose connections" on page
154
).
3. Reconfigure the drives to different SCSI ports.
1776-Drive Array Reports Improper SCSI Port 1 Cabling
Audible Beeps: None
•
•
•
•
•
Possible Cause:
The integrated array enabler board failed.
The integrated Smart Array option ROM is corrupted.
The I/O board, media backplane fan board, or media backplane failed.
Action:
Replace the integrated array enabler board.
Replace the integrated Smart Array option ROM.
CAUTION: Only authorized technicians trained by HP should
attempt to remove the I/O board. If you believe the I/O board requires
replacement, contact HP Technical Support before proceeding.
•
Rebooting after installing each item, replace in the following order: media
backplane fan board, media backplane, and I/O board.
Содержание ML370 - ProLiant - G3
Страница 8: ......
Страница 47: ...Server setup 47 7 Secure the server to the rack 8 Secure the cable management arm bracket to the server ...
Страница 52: ......
Страница 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Страница 110: ......
Страница 130: ......
Страница 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 143: ...Troubleshooting 143 ...
Страница 145: ...Troubleshooting 145 ...
Страница 147: ...Troubleshooting 147 ...
Страница 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 292: ......