228
HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide
Audible Beeps: None
Action: None.
Action: Check the System Management Log or OS Event Log for details on the
failure.
Action: Run Insight Diagnostics ("
on page
126
Possible Cause: This message indicates Mirrored Memory is enabled and
indicates the amount of memory reserved for this feature.
Action: None.
Advanced Memory Protection mode: RAID memory with Advanced
ECC
...Xxxx MB System memory and xxxx MB memory reserved for RAID.
Audible Beeps: None
Possible Cause: This message indicates RAID Memory is enabled and indicates
the amount of memory reserved for this feature.
An Unexpected Shutdown occurred prior to this power-up
Audible Beeps: None
Possible Cause: The server shut down because of an unexpected event on the
previous boot.
Critical Error Occurred Prior to this Power-Up
Audible Beeps: None
Possible Cause: A catastrophic system error, which caused the server to crash,
has been logged.
HP Insight Diagnostics"
) and
replace failed components as indicated.
Содержание ML370 - ProLiant - G3
Страница 8: ......
Страница 47: ...Server setup 47 7 Secure the server to the rack 8 Secure the cable management arm bracket to the server ...
Страница 52: ......
Страница 85: ...Hardware options installation 85 2 Release the retaining clip 3 Install the expansion board ...
Страница 110: ......
Страница 130: ......
Страница 138: ...138 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 140: ...140 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 143: ...Troubleshooting 143 ...
Страница 145: ...Troubleshooting 145 ...
Страница 147: ...Troubleshooting 147 ...
Страница 150: ...150 HP ProLiant ML370 Generation 4 Server Reference and Troubleshooting Guide ...
Страница 292: ......