Troubleshooting
M8501 and M8502 ACL Tape Drive Installation and User’s Guide — 529972-003
6 -5
Fault Symptom Codes (FSCs)
Open Doors Fault
2093
C, G
Door open sensor time-out detected when
open door.
Open DLT Handle
Fault
2094
C, G
Failed to open DLT handle.
No IP Address Found
20a0
C, G
SMC router failed to get an IP address.
No IP Address Mode
Fault
20a1
C, G
SMC router failed to detected static or ip
address Mode.
Unknown exchange
for the async
message
20b0
C, G
Unexpected exchange detected when
process Messages.
Drive In Error
20c0
C, G
Control failed to set SCSI id.
Drive In Error
20c1
C, G
Control failed to installed drive.
Drive In Error
20c0
C, G
Control failed to set SCSI id.
Drive In Error
20c1
C, G
Control failed to installed drive.
Motor Fault Condition
3000
C, G
One of the motors has been disabled and
could not be re-enabled.
Picker Tach Errors
3002
C, G
Picker Tach errors were detected when
checking slots.
Bin Fetch Failure
3001
C, G
Loader failed to fetch a cartridge from a
bin.
Drive Fetch Failure
3013
C, G
Loader failed to fetch a cartridge from the
drive.
Drive Time-out Failure
3015
C, D, G
Loader detects unload command time-
out.
Drive Status Failure
3016
C, D, G
Detected drive error from fetch, stow and
wait for handle ok DLT drive operation.
Drive In Flux Time-out
3017
C, D, G
Time-out waiting for drive to clear the flux
status.
Drive Load Retry
Failed
3018
C, G
LTO drive fail to load, detected in drive
task.
Drive OpenDoor
Failed
3019
C, G
Failed open DLT door.
Drive Close Door
Failed
301A
C, G
Failed close DLT drive door.
Drive Communication
Error
301B
C, D, G
Intertask send, receive failed.
Drive Get General
Status Fail
301C
C, D, G
Drive communication failed.
Drive Get Status 3 Fail
301D
C, D, G
NOT USED
Table 6-2. Fault Symptom Codes