14
HP MaxiLife Utility
Special Cases
1
If a CPU is not installed correctly.
Either the “Power CPUx” or “CPU socket” or “BIOS” message may
appear. This will depend on which end of the CPU connector is not
correctly inserted.
2
If a VRM is installed and there is a terminator in the associated
CPU socket.
MaxiLife displays “Power” error message and the system does not
start
3
Only one pre-boot error reported on the system.
Hidden errors will be revealed when the current error has been
fixed.
4
If a “No Video Error” message is displayed, even though the video
is working correctly.
With some specific add-on boards (for example, 1540 from
Adaptec with SCSI BIOS), this error may appear while the system
is fully working. To check if this is the case, remove all add-on
boards from the basic system configuration.
1.
Special cases: Board PLL = System board needs replacing. CPU error = Reset or power off the system to recover.
The BIOS then executes the Power On Self Test
(POST) sequence. In this phase, HP MaxiLife
waits for any error messages that the BIOS may
issue.
POST XXXX
• If the screen is working, you can obtain the signification of the
error by typing “Enter” at the end of the POST. Or, you can
check the list of errors that are available on the HP World-Wide
Web support page.
During normal usage of the PC, HP MaxiLife is
always checking vital parameters of the system.
If an error should occur, a message would be
automatically displayed on the LCD panel.
TEMP IO SLOT
• Check the connection of the corresponding component, which
could be: “Temp IO slot”, “Power errors, “Fan CPU”, “Board
PLL”, “Temp disk”, “Temp CPU”, “Fan disk”, “Fan IO slot”, “CPU
error”.
1
Test
Error Code
Action to Take
Содержание Kayak XU 03xx
Страница 42: ...42 Answers and Explanations ...
Страница 44: ...Manual Part Number D5699 90901 Revision B ...