![HP JH299A Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/hp/jh299a/jh299a_configuration-manual_162851033.webp)
24
Configuring parameters for IGMP general queries and responses globally
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter IGMP-snooping view.
igmp-snooping
N/A
3.
Set the maximum response
time
for IGMP general
queries.
max-response-time seconds
The default setting is 10 seconds.
Configuring parameters for IGMP general queries and responses in a VLAN
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter VLAN view.
vlan vlan-id
N/A
3.
Set the IGMP general query
interval in the VLAN.
igmp-snooping query-interval
interval
The default setting
is
125
seconds.
4.
Set the maximum response
time
for IGMP general
queries in the VLAN.
igmp-snooping
max-response-time seconds
The default setting is 10 seconds.
Configuring parameters for IGMP messages
This section describes how to configure parameters for IGMP messages.
Configuration prerequisites
Before you configure parameters for IGMP messages, complete the following tasks:
•
Enable IGMP snooping for the VLAN.
•
Determine the source IP address of IGMP general queries.
•
Determine the source IP address of IGMP group-specific queries.
•
Determine the source IP address of IGMP reports.
•
Determine the source IP address of IGMP leave messages.
•
Determine the 802.1p priority of IGMP messages.
Configuring source IP addresses for IGMP messages
The IGMP snooping querier might send IGMP general queries with the source IP address 0.0.0.0.
The port that receives such queries will not be maintained as a dynamic router port. This might
prevent the associated dynamic IGMP snooping forwarding entry from being correctly created at the
data link layer and eventually cause multicast traffic forwarding failures.
To avoid this problem, you can configure a non-all-zero IP address as the source IP address of the
IGMP queries on the IGMP snooping querier. This configuration might affect the IGMP querier
election within the subnet.
You can also change the source IP address of IGMP reports or leave messages sent by a simulated
member host or an IGMP snooping proxy.
To configure source IP addresses for IGMP messages in a VLAN: