19
■
VRRP (CR_0000113863)
- After a reboot, the VRRP Master configured with a preempt delay timer sends a gratuitous
ARP from the switch's physical MAC address instead of the VRRP virtual MAC address. This causes routing to fail
until the preempt delay timer expires.
Version KA.15.09.0004
Status: Released, but removed from the web due to CR_0000124276.
This software is recalled and no longer recommended.
■
CLI (CR_0000115515)
- The switch does not allow configuration changes via the CLI, responding with the error
message
inconsistent value
. This has been observed when the configuration includes
snmpv3 targetaddress
TARGETADDRESS
with a
TARGETADDRESS
string longer than 24 characters.
■
Config (CR_0000117518
) - A switch configured with a username and password and with
include-credentials
cannot
be accessed after updating software, because the username is wrongly removed from the config file during the
software update.
■
Crash (CR_0000115929)
- With very large key sizes, the command
show crypto host-cert
might cause the switch to
reboot unexpectedly with a message similar to the following.
Invalid Instr
HW Addr=0x00000000 IP=0x0 Task='mSess2' Task ID=0xa97ad40
sp:0x4acecc8 lr:0x57e468
msr: 0x02029200 xer: 0x20000000 cr: 0x28000400
■
Crash (CR_0000116647)
- It is possible for the switch to reboot unexpectedly with a message similar to the
following.
Software exception in kernel context at ghsException.c:1101
-> Internal system error
■
Module Crash (CR_0000113992)
- In a rare situation, a switch module or port bank might reboot unexpectedly
with a message similar to the following.
chassis: Slot H Read Error Restr Mem Access HW Addr=0xffaaaaf0
IP=0x1a10d64 Task='mIpAdMUpCt' Task ID=0x1b1e2300
Bus Error Data=0x00000000 Status=0x00000400
■
Module Crash (CR_0000116226)
- In a rare situation, a switch module or port bank might reboot unexpectedly
with a message similar to the following. This improves the original Module Crash fix (CR_0000113992), also in
KA.15.09.0004.
chassis: Slot H Read Error Restr Mem Access HW Addr=0xe5911000
IP=0x1a10da8 Task='mIpAdMUpCt' Task ID=0x1b1e4c80
Bus Error Data=0x00000000 Status=0x00000400
■
Power (CR_0000112424)
- When the switch is exposed to AC power fluctuations and the voltage drops too low,
the switch reboots and generates an incorrect error message saying the switch crashed. With this fix, the error
message is changed to
Switch rebooting due to temporary loss of power or low voltage
.
■
SSL (CR_0000115933)
- Under certain conditions, the VLAN -> VLAN Mgmt page on the switch cannot be accessed
via an SSL connection to the web user interface.
■
Web Management (CR_0000108339)
- The switch's web user interface cannot be accessed via the fully-qualified
domain name in some situations. Workaround: Use the IP address to access the switch's web user interface.
Содержание J9573A
Страница 1: ...HP 3800 Switches Software Version KA 15 10 0022 Release Notes ...
Страница 34: ...32 ...
Страница 35: ......