1 NS2300 System Overview
The characteristics of a NS2300 system are:
Intel® Itanium® / NSE-AG
Processor / Processor Model
42U and 36U
Rack
16 GB, 32 GB, or 48 GB
Main memory
2 or 4 (4 processor maximum)
Supported processor configurations
Supported CLuster I/O Modules (CLIMs)
•
Storage CLIMs
•
IP CLIMs for Ethernet
•
Telco CLIMs for Ethernet (M3UA protocol)
Up to 6 CLIMs using these possible combinations:
Maximum CLIMs
•
Up to 4 Storage CLIMs (two pairs)
•
Up to 2 IP CLIMs if there are 0 Telco CLIMs
•
Up to 2 Telco CLIMs if there are 0 IP CLIMs
Minimum CLIMs
•
0 IP CLIMs
•
0 Telco CLIMs
•
2 Storage CLIMs
A Storage CLIM pair supports a maximum of 4 SAS disk
enclosures (applies to all Storage CLIMs)
Maximum SAS disk enclosures
100 per Storage CLIM pair
Maximum SAS disk drives
2 required (one each for X and Y fabrics)
Maximum VIO enclosures
4 embedded Ethernet ports (one port is reserved for OSM)
Maximum embedded Ethernet connectivity per VIO
enclosure
4 optional expanded Ethernet ports (copper/optical)
Maximum expanded Ethernet connectivity per VIO
enclosure (optional)
Supported via Storage CLIM
Enterprise Storage System (ESS) support
Not supported
Fibre Channel to SCSI router support
Not supported
I/O Adapter Module (IOAM) enclosures
Not supported
Fibre Channel disk modules (FCDMs)
Not supported
Connection to NonStop ServerNet Clusters
Not supported
Connection to NonStop S-series I/O
NS2300 standard and optional hardware
describes the NS2300 system hardware. Because
NS2300 systems offer flexibility in how hardware is distributed in the rack, configurations can
vary.
shows an example configuration.
8
NS2300 System Overview
Содержание Integrity NonStop i NS2300
Страница 5: ...Ukraine RoHS material content declaration 79 Index 80 Contents 5 ...
Страница 9: ...Figure 1 Example NS2300 System Configuration 42U 9 ...
Страница 31: ...Figure 3 Intelligent PDU Connections Without UPS Power Distribution for NS2300 Systems 31 ...
Страница 33: ...Figure 5 Intelligent PDU Connections With Three Phase UPS Power Distribution for NS2300 Systems 33 ...
Страница 35: ...Figure 7 Modular PDU Connections With Single Phase UPS Power Distribution for NS2300 Systems 35 ...
Страница 36: ...Figure 8 Modular PDU Connections With Three Phase UPS 36 System Installation Specifications for NS2300 Systems ...
Страница 38: ...Figure 9 Example of Bottom AC Power Feed Without UPS 38 System Installation Specifications for NS2300 Systems ...
Страница 39: ...Figure 10 Example of Top AC Power Feed Without UPS Power Distribution for NS2300 Systems 39 ...
Страница 41: ...Figure 12 Example of Bottom AC Power Feed With Single Phase UPS Power Distribution for NS2300 Systems 41 ...